146 Configuration: Disk Groups and Virtual Disks
4
Locate the disk group, and label the physical disks.
5
Place the disk group offline.
6
Obtain blank physical disk modules or new physical disks.
On the target storage array:
1
Verify that the target storage array has available physical disk slots.
2
Verify that the target storage array supports the physical disks that you
import.
3
Verify that the target storage array can support the new virtual disks.
4
Verify that the latest version of firmware is installed on the RAID
controller module.
Import Disk Group
The import disk group operation adds the imported disk group to the target
storage array. After you complete the import disk group operation, all of the
physical disks have Optimal status. Any associated virtual disks or free
capacity nodes are now shown in MDSM installed on the target storage array.
NOTE: You lose access to your data during the export/import process.
NOTE: You must export a disk group before you move the disk group or import the
disk group.

Importing a Disk Group

NOTE: You must insert all of the physical disks that are part of the disk group into
the enclosure before the disk group can be imported.
On the target storage array:
1
Insert the exported physical disks into the available physical disk slots.
2
Review the Import Report for an overview of the disk group that you are
importing.
3
Check for non-importable components.
4
Confirm that you want to proceed with the import procedure.
NOTE: Some settings cannot be imported during the import disk group
procedure.
book.book Page 146 Thursday, December 9, 2010 3:20 PM