Management: Firmware Downloads 197
15
Management: Firmware Downloads

Downloading RAID Controller and NVSRAM

Packages

A version number exists for each firmware file. The version number indicates
whether the firmware is a major version or a minor version. You can use the
Enterprise Management Window (EMW) to download and activate both the
major firmware versions and the minor firmware versions. You can use the
Array Management Window (AMW) to download and activate only the
minor firmware versions.
NOTE: Firmware versions are of the format aa.bb.cc.dd. Where aa is the major
firmware version. bb.cc.dd is the minor firmware version. Depending on which one
changes, firmware can be updated from EMW and AMW or only EMW.
You can activate the files immediately or wait until a more convenient time.
You might want to activate the firmware or NVSRAM files at a later time
because of these reasons:
Time of da y
—Activating the firmware and the NVSRAM can take a long
time, so you can wait until I/O loads are lighter. The RAID controller
modules are offline briefly to load the new firmware.
Typ e o f p ac k ag e
—You might want to test the new firmware on one storage
array before loading the files onto other storage arrays.
The ability to download both files and activate them later depends on the
type of RAID controller module in the storage array.
NOTE: You can use the command line interface to download and activate the
firmware to several storage arrays by using a script. Refer to the PowerVault
Modular Disk Storage Manager online help topics for more information on the
command line interface.
book.book Page 197 Thursday, December 9, 2010 3:20 PM