Installing a Hard Drive Into a Drive Carrier

1Insert the hard drive into the hard-drive carrier with the connector end of the drive at the back. See Figure 16-5.

2Align the screw holes on the hard drive with the back set of holes on the hard-drive carrier.

When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.

3Attach the four screws to secure the hard drive to the hard-drive carrier.

RAID Controller Module

An MD3600i Series storage array supports single as well as dual RAID controller configurations. If only one RAID controller module is installed in your array, it must be installed in slot 0. You must install the RAID controller module blank in slot 1.

CAUTION: RAID controller modules can be removed and installed without turning off the array. It is recommended that you do not remove the RAID controller module while data is being transferred. Replacing or installing a RAID controller module that is connected to a host server causes it to loose communication with the array and may require a reboot of the host server.

Removing a RAID Controller Module Blank

CAUTION: To maintain proper system cooling, you must install a RAID controller module blank in the empty slot.

1Turn off the array and host server.

2Disconnect all the power cables connected to the array.

3To remove the RAID controller module blank, press down on the release latch and pull the blank away from the array. See Figure 16-7.

4Install RAID controller modules in slots 0 and 1. See "Installing a RAID Controller Module" on page 220.

Management: Installing Array Components

217

Page 217
Image 217
Dell MD3600I, MD3620I Installing a Hard Drive Into a Drive Carrier, Removing a RAID Controller Module Blank, 217