Hard-Drive Status Indicator Pattern

Condition

Off

Steady green

Green flashing (on 250 ms, off 250 ms) Green flashing (on 400 ms, off 100 ms) Amber flashing (on 150 ms, off 150 ms)

Flashing green, amber, and off (green on 500 ms, amber on 500 ms, off 1000 ms)

Flashing green, amber, and off (green 3 s, amber 3 s, and off 3 s)

The physical disk:

is not yet discovered by the host server

has been spun down for removal

is not supported for the RAID controller module or is not in the physical disk slot

NOTE: The drive status indicator remains off until all hard drives are initialized after system power is turned on. Drives are not ready for insertion or removal during this time.

Physical disk is online

Physical disk is being identified Physical disk rebuilding Physical disk failed

Physical disk failure predicted (SMART)

Physical disk rebuild aborted

Power Supply and Cooling Fan Features

The MD3600i Series storage array includes two integrated, hot-swappable power supply/cooling fan modules. Both modules must be installed to ensure proper cooling. Each module contains two separate cooling fans. The system requires at least one of the cooling fans to function to avoid overheating.

A power supply/cooling fan module can be replaced without powering down the system. For information on removing and replacing the modules, see "Power Supply/Cooling Fan Module" on page 224.

CAUTION: A power supply/cooling fan module can be removed from a powered- on system for a maximum period of 5 minutes. Beyond that time, the system automatically shuts down to prevent damage.

Planning: About Your Storage Array

29

Page 29
Image 29
Dell MD3600I, MD3620I owner manual Power Supply and Cooling Fan Features, Hard-Drive Status Indicator Pattern Condition