Pr.

Explanation

Settings

Factory Setting

NOTE

11.00

Multi-function

0: No function

0

 

Output Terminal

1: AC drive operational

 

 

MO2/RA2

2: Master frequency attained

 

 

 

Multi-function

3: Zero speed

 

 

11.01

Output Terminal

4: Over torque detection

0

 

 

MO3/RA3

5: Base-Block (B.B.) indication

 

 

 

 

6: Low-voltage indication

 

 

 

 

 

 

 

 

7: Operation mode indication

 

 

 

Multi-function

8: Fault indication

 

 

11.02

Output Terminal

9: Desired frequency 1 attained

0

 

 

MO4/RA4

10: Terminal count value attained

 

 

 

 

11: Preliminary count value attained

 

 

 

 

12: Over Voltage Stall supervision

 

 

 

Multi-function

13: Over Current Stall supervision

 

 

11.03

Output Terminal

14: Heat sink overheat warning

0

 

 

MO5/RA5

15: Over Voltage supervision

 

 

 

Multi-function

16: PID supervision

 

 

11.04

Output Terminal

17: Forward command

0

 

 

MO6/RA6

18: Reverse command

 

 

 

 

19: Zero speed output signal

 

 

 

Multi-function

20: Warning(FbE,Cexx, AoL2, AUE, SAvE)

 

 

 

21: Brake control (Desired frequency

0

 

11.05

Output Terminal

 

attained)

 

 

MO7/RA7

 

 

 

22: Drive ready

 

 

 

 

 

 

 

 

23: Desired frequency 2 attained

 

 

 

Multi-function Input

0: No function

0

 

11.06

1: Multi-Step speed command 1

 

 

Terminal (MI7)

2: Multi-Step speed command 2

 

 

 

 

 

 

 

3: Multi-Step speed command 3

 

 

 

Multi-function Input

4: Multi-Step speed command 4

0

 

11.07

5: External reset

 

 

Terminal (MI8)

6: Accel/Decel inhibit

 

 

 

 

 

 

 

7: Accel/Decel time selection command

 

 

 

 

8: Jog Operation

 

 

 

 

0

 

 

Multi-function Input

9: External base block

 

11.08

 

 

Terminal (MI9)

10: Up: Increment master frequency

 

 

 

 

 

 

 

11: Down: Decrement master frequency

 

 

 

 

12: Counter Trigger Signal

 

 

 

 

0

 

 

Multi-function Input

13: Counter reset

 

11.09

 

 

14: E.F. External Fault Input

 

 

Terminal (MI10)

 

 

 

15: PID function disabled

 

 

 

 

 

 

 

 

16: Output shutoff stop

 

 

 

 

0

 

 

 

17: Parameter lock enable

 

11.10

Multi-function Input

18: Operation command selection (external

 

 

Terminal (MI11)

terminals)

 

 

 

 

 

 

 

19: Operation command selection (keypad)

 

 

 

 

20: Operation command selection

 

 

11.11

Multi-function Input

(communication)

0

 

 

Terminal (MI12)

21: FWD/REV command

 

 

 

 

22: Source of second frequency command

 

 

 

 

23: Run/Stop PLC Program (PLC1) (NOT

 

 

 

 

for VFD*E*C models)

 

 