Fault

 

Fault Descriptions

 

 

Corrective Actions

 

 

Name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANopen SYNC Time out

Check if CANopen synchronous message is

 

 

 

 

(Only for VFDxxxExxC)

abnormal

 

 

 

CANopen SDO Time out

Check if command channels are full

 

 

 

 

(Only for VFDxxxExxC)

 

 

 

 

 

 

 

CANopen SDO buffer

1.

Too short time between commands, please

 

 

 

 

overflow (Only for

 

check SDO message sent from the master

 

 

 

VFDxxxExxC)

2.

Reset CAN bus

 

 

 

CAN bus off (Only for

1.

Check if it connects to terminal resistor

 

 

 

 

VFDxxxExxC)

2.

Check if the signal is abnormal

3.Check if the master is connected

CAN Boot up fault (Only for

1.

Check if the master is connected

VFDxxxExxC)

2.

Reset CAN bus

Error communication protocol

Check if the communication protocol is correct

of CANopen (Only for

 

 

VFDxxxExxC)

 

 

Dimensions are in mm [inch]

Frame A

W

W1

D

D1

D2

H1 H

S1

S2

Unit: mm [inch]

 

Frame

W

W1

H

H1

D

D1

D2

S1

S2

 

A (A1)

72.0

60.0

142.0

120.0

152.0

50.0

4.5

5.2

5.2

 

[2.83]

[2.36]

[5.59]

[4.72]

[5.98]

[1.97]

[0.18]

[0.20]

[0.20]

 

 

 

A (A2)

72.0

56.0

155.0

143.0

111.5

9.5

-

5.3

-

 

[2.83]

[2.20]

[6.10]

[5.63]

[4.39]

[0.37]

 

[0.21]

 

 

 

 

 

English- 34

Page 34
Image 34
Delta Electronics VFD-XXXE quick start Dimensions are in mm inch, Frame