| Pr. | Explanation | Settings | Factory | NOTE |
|
|
| Setting |
| ||||
|
|
|
|
|
|
| |
|
|
|
| 0: Disabled |
|
|
|
|
|
|
| 1: Enabled during constant speed operation. |
|
|
|
|
|
|
| After the |
|
|
|
|
|
|
| running until OL1 or OL occurs. |
|
|
|
|
|
| 2: Enabled during constant speed operation. |
|
|
| |
|
|
| After the |
|
|
| |
06.03 | Detection Mode | 0 |
|
| |||
running. |
|
| |||||
|
|
| (OL2) |
|
|
| |
|
|
| 3: Enabled during accel. After the over- |
|
|
| |
|
|
|
|
|
|
| |
|
|
|
| torque is detected, keep running until OL1 or |
|
|
|
|
|
|
| OL occurs. |
|
|
|
|
|
|
| 4: Enabled during accel. After the over- |
|
|
|
|
|
|
| torque is detected, stop running. |
|
|
|
06.04 | 10 to 200% | 150 |
|
| |||
Detection Level |
|
| |||||
|
|
|
|
|
|
| |
06.05 | 0.1 to 60.0 sec | 0.1 |
|
| |||
Detection Time |
|
| |||||
|
|
|
|
|
|
| |
|
|
| Electronic Thermal | 0: Standard motor (self cooled by fan) |
|
|
|
06.06 | Overload Relay | 1: Special motor (forced external cooling) | 2 |
|
| ||
|
|
| Selection | 2: Disabled |
|
|
|
06.07 | Electronic Thermal | 30 to 600 sec | 60 |
|
| ||
Characteristic |
|
| |||||
|
|
|
|
|
|
| |
|
|
|
| 0: No fault |
|
|
|
|
|
|
| 1: Over current (oc) |
|
|
|
|
|
| Present Fault | 2: Over voltage (ov) |
|
|
|
06.08 | 3: IGBT Overheat (oH1) | 0 |
|
| |||
Record |
|
| |||||
|
|
| 4: Power Board Overheat (oH2) |
|
|
| |
|
|
|
|
|
|
| |
|
|
|
| 5: Overload (oL) |
|
|
|
|
|
|
| 6: Overload1 (oL1) |
|
|
|
| 06.09 | Second Most | 7: Motor over load (oL2) |
|
|
| |
|
|
| Recent Fault Record | 8: External fault (EF) |
|
|
|
|
|
|
| 9: Current exceeds 2 times rated current |
|
|
|
|
|
|
| during accel.(ocA) |
|
|
|
|
|
|
| 10: Current exceeds 2 times rated current |
|
|
|
|
|
|
| during decel.(ocd) |
|
|
|
|
|
|
| 11: Current exceeds 2 times rated current |
|
|
|
|
|
|
| during steady state operation (ocn) |
|
|
|
|
|
|
| 12: Ground fault (GFF) |
|
|
|
|
|
|
| 13: Reserved |
|
|
|
|
|
|
| 14: |
|
|
|
|
|
|
| 15: Reserved |
|
|
|
|
|
|
| 16: Auto Acel/Decel failure (CFA) |
|
|
|
|
|
|
| 17: SW/Password protection (codE) |
|
|
|
06.10 | Third Most Recent | 18: Power Board CPU WRITE failure (cF1.0) |
|
|
| ||
19: Power Board CPU READ failure (cF2.0) |
|
|
| ||||
Fault Record |
|
|
| ||||
|
|
| 20: CC, OC Hardware protection failure |
|
|
| |
|
|
|
|
|
|
| |
|
|
|
| (HPF1) |
|
|
|
|
|
|
| 21: OV Hardware protection failure (HPF2) |
|
|
|
|
|
|
| 22: GFF Hardware protection failure (HPF3) |
|
|
|
|
|
|
| 23: OC Hardware protection failure (HPF4) |
|
|
|
|
|
|
| 24: |
|
|
|
|
|
|
| 25: |
|
|
|
|
|
|
| 26: |
|
|
|
|
|
|
|
|
|
|
|