Delta Electronics VFD-XXXE Group 1 Basic Parameters, For VFD*E*C models, the factory setting is

Models: VFD-XXXE

1 36
Download 36 pages 29.99 Kb
Page 12
Image 12

 

 

Pr.

Explanation

Settings

Factory

NOTE

 

 

 

Setting

 

 

 

 

 

 

 

 

00.12

50Hz Base Voltage

0: 230V/400V

0

 

 

Selection

1: 220V/380V

 

 

 

 

 

 

 

 

 

 

 

 

Group 1 Basic Parameters

 

 

 

01.00

Maximum Output

50.00 to 600.0 Hz

60.00

 

 

Frequency (Fmax)

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Voltage

 

 

 

 

01.01

Frequency (Fbase)

0.10 to 600.0 Hz

60.00

 

 

 

 

 

(Motor 0)

 

 

 

 

01.02

Maximum Output

115V/230V series: 0.1V to 255.0V

220.0

 

 

Voltage (Vmax)

460V series: 0.1V to 510.0V

440.0

 

 

 

 

 

(Motor 0)

 

 

 

 

 

 

 

 

01.03

Mid-Point Frequency

0.10 to 600.0 Hz

1.50

 

 

 

 

 

(Fmid) (Motor 0)

 

 

 

 

01.04

Mid-Point Voltage

115V/230V series: 0.1V to 255.0V

10.0

 

 

(Vmid) (Motor 0)

460V series: 0.1V to 510.0V

20.0

 

 

 

 

 

 

 

 

 

 

Minimum Output

 

 

 

 

01.05

Frequency (Fmin)

0.10 to 600.0 Hz

1.50

 

 

 

 

 

(Motor 0)

 

 

 

 

01.06

Minimum Output

115V/230V series: 0.1V to 255.0V

10.0

 

 

Voltage (Vmin)

 

 

 

460V series: 0.1V to 510.0V

20.0

 

 

 

 

 

(Motor 0)

 

 

 

 

 

 

 

 

 

01.07

Output Frequency

0.1 to 120.0%

110.0

 

 

Upper Limit

 

 

 

 

 

 

 

 

 

 

01.08

Output Frequency

0.0 to100.0 %

0.0

 

 

Lower Limit

 

 

 

 

 

 

 

 

 

 

 

01.09

Accel Time 1

0.1 to 600.0 / 0.01 to 600.0 sec

10.0

 

 

 

01.10

Decel Time 1

0.1 to 600.0 / 0.01 to 600.0 sec

10.0

 

 

01.11

Accel Time 2

0.1 to 600.0 / 0.01 to 600.0 sec

10.0

 

 

For VFD*E*C models, the factory setting is 1.0

 

 

 

 

 

 

 

 

01.12

Decel Time 2

0.1 to 600.0 / 0.01 to 600.0 sec

10.0

 

 

For VFD*E*C models, the factory setting is 1.0

 

 

 

 

 

 

 

 

01.13

Jog Acceleration

0.1 to 600.0 / 0.01 to 600.0 sec

1.0

 

 

Time

 

 

 

 

 

 

 

 

 

 

01.14

Jog Deceleration

0.1 to 600.0 / 0.01 to 600.0 sec

1.0

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

01.15

Jog Frequency

0.10 Hz to Fmax (Pr.01.00) Hz

6.00

 

 

 

 

 

 

0: Linear Accel/Decel

 

 

 

 

 

 

Auto acceleration /

1: Auto Accel, Linear Decel

 

 

 

01.16

deceleration (refer

2: Linear Accel, Auto Decel

0

 

 

to Accel/Decel time

3: Auto Accel/Decel (Set by load)

 

 

 

 

 

 

 

 

 

 

 

setting)

4: Auto Accel/Decel (set by Accel/Decel

 

 

 

 

 

 

 

Time setting)

 

 

 

01.17

Acceleration S-

0.0 to 10.0 / 0.00 to 10.00 sec

0.0

 

 

Curve

 

 

 

 

 

 

 

 

 

01.18

Deceleration S-

0.0 to 10.0 / 0.00 to 10.00 sec

0.0

 

 

Curve

 

 

 

 

 

 

 

 

 

01.19

Accel/Decel Time

0: Unit: 0.1 sec

0

 

 

Unit

1: Unit: 0.01 sec

 

 

 

 

 

 

 

 

01.20

Delay Time at 0Hz

0.00 to 600.00 sec

0.00

 

 

 

 

 

for Simple Position

 

 

 

 

English- 12

Page 12
Image 12
Delta Electronics VFD-XXXE quick start Group 1 Basic Parameters, For VFD*E*C models, the factory setting is