Delta Tau 5xx-603869-xUxx Suggested M-Variable Addressing for the General Purpose I/O J6, Sinking

Models: 5xx-603869-xUxx

1 50
Download 50 pages 42.72 Kb
Page 26
Image 26
Suggested M-Variable Addressing for the General Purpose I/O (J6)

Brick Motion Controller Hardware Reference Manual

Suggested M-Variable Addressing for the General Purpose I/O (J6)

Suggested M-var. #

Address

Notes

 

 

M0->

Y:$78800,0,1

Input 1 Data Line, J6 Pin 1

 

 

M1->

Y:$78800,1,1

Input 2 Data Line, J6 Pin 20

 

 

M2->

Y:$78800,2,1

Input 3 Data Line, J6 Pin 2

 

 

M3->

Y:$78800,3,1

Input 4 Data Line, J6 Pin 21

 

 

M4->

Y:$78800,4,1

Input 5 Data Line, J6 Pin 3

 

 

M5->

Y:$78800,5,1

Input 6 Data Line, J6 Pin 22

 

 

M6->

Y:$78800,6,1

Input 7 Data Line, J6 Pin 4

 

 

M7->

Y:$78800,7,1

Input 8 Data Line, J6 Pin 23

 

 

M8->

Y:$78801,0,1

Input 9 Data Line, J6 Pin 5

 

 

M9->

Y:$78801,1,1

Input 10 Data Line, J6 Pin 24

 

 

M10->

Y:$78801,2,1

Input 11 Data Line, J6 Pin 6

 

 

M11->

Y:$78801,3,1

Input 12 Data Line, J6 Pin 25

 

 

M12->

Y:$78801,4,1

Input 13 Data Line, J6 Pin 7

 

 

M13->

Y:$78801,5,1

Input 14 Data Line, J6 Pin 26

 

 

M14->

Y:$78801,6,1

Input 15 Data Line, J6 Pin 8

 

 

M15->

Y:$78801,7,1

Input 16 Data Line, J6 Pin 27

 

 

M32->

Y:$078802,0,1

Output 1 Data Line

12

30

M33->

Y:$078802,1,1

Output 2 Data Line

13

31

M34->

Y:$078802,2,1

Output 3 Data Line

14

32

M35->

Y:$078802,3,1

Output 4 Data Line

15

33

M36->

Y:$078802,4,1

Output 5 Data Line

16

34

M37->

Y:$078802,5,1

Output 6 Data Line

17

35

M38->

Y:$078802,6,1

Output 7 Data Line

18

36

M39->

Y:$078802,7,1

Output 8 Data Line

19

37

Do not mix topologies, i.e.,

all sinking or all sourcing outputs. If the common emitter is used, the

Sourcing

Sinking

common collector should be unconnected. Conversely, if the common collector is used, the common

emitter should be unconnected.

 

 

 

 

 

 

 

 

 

18

System Wiring

Page 26
Image 26
Delta Tau 5xx-603869-xUxx Suggested M-Variable Addressing for the General Purpose I/O J6, Suggested M-var. #, Sourcing