Setting up for Pulse and Direction Output

Brick Motion Controller Hardware Reference Manual

Setting up for Pulse and Direction Output

The following section shows how to quickly setup the key variables for a stepper motor (PFM) system.

The step and direction outputs are RS422 compatible and are capable of being connected in either differential mode or single ended configurations for 5V input drivers.

Below are two examples for wiring the Brick Motion Controller to the stepper Amplifier. The user needs to write pin 8 to pin 4 so as to enable the Stepper output and the AENA.

GBL_Stepper output wiring X1-X8,

quadrature encoder feedback, Amplifier Enable lines are used

1GBL_Stepper output wiring X1-X8,quadrature encoder feedback, Amplifier Enable lines are usedAmplifier Enable lines are used CHAn+

9Software SetupMulti-Channel Servo IC I-Variables CHAn-

2

10

CHBn+

 

 

CHBn-

 

3

 

ENCPWR

 

11

AENAn+/index +

 

4

AENAn-/index -

 

 

 

 

5

12

GND

 

13

DIRn+

Stepper

6

DIRn-

14

PULn+

Amplifier

7

PULn-

Shield

 

 

15I7m00: Servo IC m MaxPhase/PWM Frequency Control

8I7m03: Servo IC m Hardware Clock Frequency Control

Short pin 8 to pin 4 to enable Stepper Output

GBL_Stepper output wiring X1-X8,

no encoder feedback

Amplifier Enable lines are used

1

9

 

 

2

 

 

10

 

 

3

AENAn+

Shield

 

11

AENAn-

 

4

 

 

 

 

 

12

GND

 

5

DIRn+

Stepper

13

DIRn-

6

PULn+

Amplifier

14

PULn-

 

7Manual background

15Manual background

8Manual background

Short pin 8 to pin 4 to enable Stepper Output

(For Older version Brick Motion Controllers: Jumpers E21(E31) throughE24( E34) must be jumpered in the inside of the unit for PFM outputs and E25(35) through E28(38) must be jumpered for amplifier enable outputs. Pin 8 was not connected to anything)

Software Setup

After having the hardware ready for steppers the user needs to set the software for Pulse and direction output as well. There are several I-variables that must be set up properly for proper operation of the Pulse and direction output in a Brick Motion Controller system. It is recommended for the user to also look into the Turbo Software reference and the Turbo Users manual. The most important ones are analyzed below and we can separate them into two categories:

Multi-Channel Servo IC I-Variables

I7m00: Servo IC m MaxPhase/PWM Frequency Control

Typically, this will be set to the same value as the variable that controls the system clocks: I7000 (channels 1-4) I7100 (channels 5-8). If a different PWM frequency is desired, then the following constraint should be observed in setting this variable:

2 * PWMFreq( kHz ) = { Integer }

PhaseFreq

I7m03: Servo IC m Hardware Clock Frequency Control

The hardware clock frequencies for the Servo IC should be set according to the devices attached to it. There is no reason that these frequencies have to be the same between ICs. There is seldom a reason to change this value from the default. At default this value will be 2258, which is to a PFM clock of approximately 10 MHz, (which is about 10 times greater than normally needed). Therefore, this value is not normally changed. Refer to the Turbo Software Reference manual for changing these variables.

System Wiring