Delta Tau 5xx-603869-xUxx J7 Extra General Purpose I/O Optional, Symbol, Function, Female DB-37

Models: 5xx-603869-xUxx

1 50
Download 50 pages 42.72 Kb
Page 27
Image 27
J7: Extra General Purpose I/O (Optional)

Brick Motion Controller Hardware Reference Manual

J7: Extra General Purpose I/O (Optional)

General purpose I/O is available on the Brick Motion Controller. All I/O is electrically isolated from the drive. Inputs can be configured for sinking or sourcing applications. All Inputs are 12-24VDC. All Outputs are 24V nominal operation, 0.5A maximum current. Outputs are robust against ESD and overload.

J7 General Purpose I/O

19

18 17

16

15

 

14

13

12

11

10

9

 

8

7 6

5

4

3

2

1

 

(Female DB-37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

36

35

34

33

32

31

 

30

29

28

27

26

25

24

23

22

21

20

 

Connector)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin #

Symbol

Function

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

1

GPIN17

Input

 

Input 17

 

 

 

 

 

 

 

 

 

 

 

 

 

2

GPIN19

Input

 

Input 19

 

 

 

 

 

 

 

 

 

 

 

 

 

3

GPIN21

Input

 

Input 21

 

 

 

 

 

 

 

 

 

 

 

 

 

4

GPIN23

Input

 

Input 23

 

 

 

 

 

 

 

 

 

 

 

 

 

5

GPIN25

Input

 

Input 25

 

 

 

 

 

 

 

 

 

 

 

 

 

6

GPIN27

Input

 

Input 27

 

 

 

 

 

 

 

 

 

 

 

 

 

7

GPIN29

Input

 

Input 29

 

 

 

 

 

 

 

 

 

 

 

 

 

8

GPIN31

Input

 

Input 31

 

 

 

 

 

 

 

 

 

 

 

 

 

9

IN_COM 17-24

Input

 

Input 17 to 24 Common

 

 

 

 

 

 

 

 

 

10

N.C

 

 

 

Not Connected

 

 

 

 

 

 

 

 

 

 

 

11

COM_EMT

Input

 

Common Emitter **

 

 

 

 

 

 

 

 

 

12

GPO9-

Output

 

Sourcing Output 9 **

 

 

 

 

 

 

 

 

 

13

GPO10-

Output

 

Sourcing Output 10 **

 

 

 

 

 

 

 

 

 

14

GPO11-

Output

 

Sourcing Output 11**

 

 

 

 

 

 

 

 

 

15

GPO12-

Output

 

Sourcing Output 12 **

 

 

 

 

 

 

 

 

 

16

GPO13-

Output

 

Sourcing Output 13 **

 

 

 

 

 

 

 

 

 

17

GPO14-

Output

 

Sourcing Output 14 **

 

 

 

 

 

 

 

 

 

18

GPO15-

Output

 

Sourcing Output 15 **

 

 

 

 

 

 

 

 

 

19

GPO16-

Output

 

Sourcing Output 16 **

 

 

 

 

 

 

 

 

 

20

GPIN18

Input

 

Input 18

 

 

 

 

 

 

 

 

 

 

 

 

 

21

GPIN20

Input

 

Input 20

 

 

 

 

 

 

 

 

 

 

 

 

 

22

GPIN22

Input

 

Input 22

 

 

 

 

 

 

 

 

 

 

 

 

 

23

GPIN24

Input

 

Input 24

 

 

 

 

 

 

 

 

 

 

 

 

 

24

GPIN26

Input

 

Input 26

 

 

 

 

 

 

 

 

 

 

 

 

 

25

GPIN28

Input

 

Input 28

 

 

 

 

 

 

 

 

 

 

 

 

 

26

GPIN30

Input

 

Input 30

 

 

 

 

 

 

 

 

 

 

 

 

 

27

GPIN32

Input

 

Input 32

 

 

 

 

 

 

 

 

 

 

 

 

 

28

IN_COM_25-32

Input

 

Input 25 to 32 Common

 

 

 

 

 

 

 

 

 

29

COM_COL

Input

 

Common Collector *

 

 

 

 

 

 

 

 

 

30

GPO9+

Output

 

Sinking Output 9 *

 

 

 

 

 

 

 

 

 

 

31

GPO10+

Output

 

Sinking Output 10 *

 

 

 

 

 

 

 

 

 

 

32

GPO11+

Output

 

Sinking Output 11 *

 

 

 

 

 

 

 

 

 

 

33

GPO12+

Output

 

Sinking Output 12 *

 

 

 

 

 

 

 

 

 

 

34

GPO13+

Output

 

Sinking Output 13 *

 

 

 

 

 

 

 

 

 

 

35

GPO14+

Output

 

Sinking Output 14 *

 

 

 

 

 

 

 

 

 

 

36

GPO15+

Output

 

Sinking Output 15 *

 

 

 

 

 

 

 

 

 

 

37

GPO16+

Output

 

Sinking Output 16 *

 

 

 

 

 

 

 

 

 

*For sinking outputs, connect the COM_EMT (pin11) line to the Analog GND of the Power supply and the

outputs to the individual plus output lines, e.g. GPO9+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**For sourcing outputs, connect the COM_COL (pin29) line to 12-24V and the outputs to the individual

 

minus output lines, e.g., GPO9-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the common

collector should be unconnected. Conversely, if the common collector is used, the common emitter should be

unconnected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

Page 27
Image 27
Delta Tau 5xx-603869-xUxx J7 Extra General Purpose I/O Optional, Symbol, Function, J7 General Purpose I/O, Female DB-37