The following describes the display panel configuration/diagnostic process:

1.

Press Right

Displays current node number

2.

Press Right

Line Card T1 Line Select

3.

Press Right

goes to Diagnostic Test 1

Press Left changes node number

Press Left selects Line Interface or Drop & Insert (if no left press at Line Card T1 Line Select)

4.

Press Right

if Drop & Insert

Press Left changes EQ

0.6 1.2

1.8 2.4 3.0

5.

Press Right

goes to Diagnostic Test 1

 

 

 

 

6.

Press Right

if Line Interface

Press Left selects CSU Long Haul or DSX-1 Short Haul

7.

Press Right

if CSU Long Haul

Press Left selects AMI/D4 or B8ZS/ESF

8.

Press Right

either AMI/D4 or B8ZS/ESF

Press Left selects Jitter, EGL, LBO

 

9.

Press Right

goes to Diagnostic Test 1

(if no left press to select Jitter, EGL, LBO)

10.

Press Right

if Jitter

Press Left selects Rx or Tx

 

 

11.

Press Right

go to step 8 above

 

 

 

 

12.

Press Right

if EGL

Press Left selects 26 or 36

 

 

13.

Press Right

go to step 8 above

 

 

 

 

14.

Press Right

if LBO

Press Left selects

00

75 15

22

15.

Press Right

go to step 8 above

 

 

 

 

By pressing <Enter> at any time, you may exit the configuration/diagnostic mode without saving any of your changes. The POST will then resume if it had not been completed at the time you entered configuration/diagnostic mode. If POST had been completed when you entered configuration/diagnostic mode, the download will begin when you exit configuration/diagnostic mode.

To exit the configuration/diagnostic mode and save your changes, cycle the T1 Modem Bank’s power off, then on again to return to the initialized state.