Digi 90031300 manual T1 Modem Bank

Models: 90031300

1 160
Download 160 pages 30.24 Kb
Page 56
Image 56

The following describes the display panel configuration/diagnostic process:

1.

Press Right

Displays current node number

2.

Press Right

Line Card T1 Line Select

3.

Press Right

goes to Diagnostic Test 1

Press Left changes node number

Press Left selects Line Interface or Drop & Insert (if no left press at Line Card T1 Line Select)

4.

Press Right

if Drop & Insert

Press Left changes EQ

0.6 1.2

1.8 2.4 3.0

5.

Press Right

goes to Diagnostic Test 1

 

 

 

 

6.

Press Right

if Line Interface

Press Left selects CSU Long Haul or DSX-1 Short Haul

7.

Press Right

if CSU Long Haul

Press Left selects AMI/D4 or B8ZS/ESF

8.

Press Right

either AMI/D4 or B8ZS/ESF

Press Left selects Jitter, EGL, LBO

 

9.

Press Right

goes to Diagnostic Test 1

(if no left press to select Jitter, EGL, LBO)

10.

Press Right

if Jitter

Press Left selects Rx or Tx

 

 

11.

Press Right

go to step 8 above

 

 

 

 

12.

Press Right

if EGL

Press Left selects 26 or 36

 

 

13.

Press Right

go to step 8 above

 

 

 

 

14.

Press Right

if LBO

Press Left selects

00

75 15

22

15.

Press Right

go to step 8 above

 

 

 

 

By pressing <Enter> at any time, you may exit the configuration/diagnostic mode without saving any of your changes. The POST will then resume if it had not been completed at the time you entered configuration/diagnostic mode. If POST had been completed when you entered configuration/diagnostic mode, the download will begin when you exit configuration/diagnostic mode.

To exit the configuration/diagnostic mode and save your changes, cycle the T1 Modem Bank’s power off, then on again to return to the initialized state.

46

T1 Modem Bank

Page 56
Image 56
Digi 90031300 manual T1 Modem Bank