S18 Modem Test Timer

Sets the length of time, in seconds, that the modem conducts a test (commanded by &Tn) before returning to the command mode. If this register value is zero, the test will not automatically terminate; the test must be terminated from the command mode by issuing an &T0 or H command.

Range: 0-255 seconds

Default: 000

S19 AutoSync Protocol Support Mode

Default = (1Ah) (26d) (00011010b)

Bit 0 Reserved

Bit 1 0 Bisync protocol

1 HDLC protocol

Bit 2

0

Address detector disabled

 

1

Address detector enabled

Bit 3

0

NRZI bit coding

 

1

NRZ bit coding

Bit 4

0

Selects mark idle

 

1

Selects flag idle

Bit 5-7

Reserved

S20 AutoSync HDLC Address

Default = 255

In HDLC mode: HDLC address.

In Bisync mode: definition of Bisync sync character.