2
Basic Switch Configuration Procedures
Reading Hexadecimal Port Diagrams
Many of the commands return port diagrams in hexadecimal format.
Example | switch:admin> bcastShow |
|
Group Member Ports Member ISL Ports | Static ISL Ports |
256 | 0x00012083 | 0x00002080 | 0x00000000 |
To read the hexadecimal port diagrams, they must be converted into binary notation. Each hexadecimal value represents four binary values. Each hexadecimal value is converted into a group of four binary values that represent four ports as follows:
Hex value = Binary value
0 = 0000
1 = 0001
2 = 0010
3 = 0011
4 = 0100
5 = 0101
6 = 0110
7 = 0111
8 = 1000
9 = 1001
A = 1010
B = 1011
C = 1100
D = 1101
E = 1110
F = 1111
Departmental Switch | |
|
|