Displaying Error Logs and Status

For more information on the portErrShow command, refer to the

Departmental Switch Model DS-16B2 Fabric OS Reference Manual.

Displaying the Error Log of a Switch

There are two ways to display the error log of a switch:

Display the error log one page at a time

Display the error log all at once

To display the switch error log one page at a time:

1.Log in to the switch as the admin user.

2.At the command line, enter the following command:

ErrShow

To display the switch error log all at once:

1.Log in to the switch as the admin user.

2.At the command line, enter the following command:

ErrDump

Displaying the Switch Status

The switch status can be Healthy/OK, Marginal/Warning, or Down. The overall status of a switch is determined by the status of several individual components within the switch. For more information on how the overall switch status is determined, refer to the switchStatusPolicySet command in the Departmental Switch Model DS-16B2 Fabric OS Reference Manual.

To display the overall status of a switch:

1.Log in to the switch as the admin user.

2.At the command line enter the following command: switchStatusShow

The status of the switch should be Healthy/OK. If the status is Marginal/Warning or Down, the components contributing to this status are displayed.

3-4

Departmental Switch Model DS-16B2 Fabric OS Procedures Manual

 

 