3

Displaying Error Logs and Status

Displaying the Uptime of the Switch

To display the uptime for a switch:

1.Log in to the switch as the admin user.

2.At the command line, enter the following command: uptime

This command displays:

The length of time the system has been in operation.

The total cumulative amount of up time since the system was first powered on.

The date and time of the last reboot.

The reason for the last reboot.

The reason for the last switch reboot is also recorded in the error log.

Displaying the Fan Status

To display the fan status of a switch:

1.Log in to the switch as the admin user.

2.At the command line, enter the following command: fanShow

The possible values for fan status are:

OK — Fan is functioning correctly.

absent — Fan is not present.

below minimum — Fan is present but rotating too slowly or stopped.

3-6

Departmental Switch Model DS-16B2 Fabric OS Procedures Manual

 

 

Page 36
Image 36