Displaying Error Logs and Status
Displaying the Uptime of the Switch
To display the uptime for a switch:
1.Log in to the switch as the admin user.
2.At the command line, enter the following command: uptime
This command displays:
•The length of time the system has been in operation.
•The total cumulative amount of up time since the system was first powered on.
•The date and time of the last reboot.
•The reason for the last reboot.
•The reason for the last switch reboot is also recorded in the error log.
Displaying the Fan Status
To display the fan status of a switch:
1.Log in to the switch as the admin user.
2.At the command line, enter the following command: fanShow
The possible values for fan status are:
•OK — Fan is functioning correctly.
•absent — Fan is not present.
•below minimum — Fan is present but rotating too slowly or stopped.