3

Displaying Error Logs and Status

Displaying the Temperature Status

To display the temperature status of a switch:

1.Login to the switch as the admin user.

2.At the command line enter the following command: tempShow

This command displays current temperature readings from each of the five temperature sensors located on the main printed circuit board of the switch. The sensors are located, approximately, one in each corner and one at the center of the PCB.

Running Diagnostic Tests on the Switch Hardware

There are several diagnostic tests you can run on a switch. These tests are generally run during the POST, each time a switch is booted up.

camtest

centralMemoryTest

cmemRetentionTest

cmiTest

crossPortTest

portLoopbackTest

sramRetentionTest

turboRamTest

statsTest

spinSilk

supportShow

The supportShow command is used to gather switch information for debugging purposes. Your EMC Customer Service representative may ask you to run this command and capture the output. This information will aid Customer Service in diagnosing problems that could occur on the switch.

3-8

Departmental Switch Model DS-16B2 Fabric OS Procedures Manual

 

 

Page 38
Image 38
EMC DS-16B2 manual Displaying the Temperature Status, Running Diagnostic Tests on the Switch Hardware, SupportShow