Boot Crashdump

3

Configuring an EMC Boot Device

Boot Crashdump

If you system is configured to write crashdumps after system failures,

Save to Disk

and the host is configured to boot from the array, you will be able to

Behavior

successfully save the crashdump only on the original available boot

 

device path on which the system started. This is a Windows

 

limitation, and installing PowerPath will not affect this behavior. At

 

the time a system crash is to be written to disk, Windows has already

 

saved the original boot path, and PowerPath cannot redirect the

 

crashdump file (MEMORY.DMP) to an alternative available device. If

 

you have a configuration for which you want to capture a

 

crashdump, you should ensure that the original primary boot path is

 

available at the time of the crash.