Installing and Configuring the HBA Driver
7.Enter a value for the loop ID and press ENTER.
8.Press ESC to return to the Configuration Settings menu.
9.Press ESC to return to the Fast!UTIL Options menu.
10.When prompted to save changes made to the current adapter, select Save Changes and press ENTER.
11.If there are more adapters to configure, choose Select Host Adapter, and repeat steps 3 through 11 for each adapter.
12.Press ESC to exit Fast!UTIL.
13.Reboot the host.
14.Repeat this procedure on all nodes in the cluster connected to the
15.While you are in the BIOS, you can verify that the topology is set correctly for direct connect
!CAUTION
Future use of the firmware NVRAM file to apply settings will overwrite and possibly invalidate the changes made above. If you will later update using a firmware NVRAM file, be sure it is listed and supports this
To restore EMC default HBA settings, either reload the approved EMC NVRAM file, or return to step 5 and ensure that Adapter Hard Loop ID is set to Disabled.
Installing an HBA | |
|
|