Configuring the HP ProLiant BL20p G2
Configuring an EMC Boot Device
3.To disconnect all SCSI hard disk drives, unplug the power and SCSI bus cables connected to a SCSI adapter or controller. For details, see the installation and operation manual for your server.
4.To prepare your system to boot Windows over a Fibre Channel connection, you must do the following:
For detailed instructions on the HP ProLiant BL20p G2, refer to Configuring the HP ProLiant BL20p G2. For other detailed instructions, refer to the manufacturer’s documentation available for each adapter.
•For any server with IDE
•Disable or remove any IDE HDD drives.
•For servers with SCSI
If the
•Disable BIOS on any other HBA BIOS in your system other than the QLogic HBA(s) designated for booting. See the documentation that accompanied the HBA for instructions.
Reboot the BL20p G2 and select F9 to RBSU (F10 to save all changes before exit):
1.Select Set Boot Controller Order:
a.Ctrl:1 PCI Dual Port Fibre..Port 1
b.Ctrl:2 PCI Dual Port Fibre..Port 2
c.Ctrl:3 HP Smart Array 5i Ctrl
2.Set the IPL order as follows:
a.PCI Embedded HP NC7781 Gig Server Adapter Port 1
b.
c.Floppy Drive
d.Hard Drive C:
Configuring a CLARiiON Boot Device | |
|
|
3