Operation

Figure 3 Main Display Screen, typical

Mimic

Display

 

Multipurpose

 

Display

Active

 

Event

Menu

Window

Bar

 

Figure 4

Mimic display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass

 

 

 

BYPASS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

L-L

0

0

0

V

 

 

 

 

 

 

 

BFB

 

 

 

 

 

 

 

 

 

Freq

0.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS

 

 

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC BUS

 

 

 

 

 

 

 

 

 

A

B

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

L-L

0

0

0

V

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

0V

 

 

 

 

 

Power

 

I

0

0

0

A

 

 

CB1

 

 

 

 

 

 

 

Current

Float

 

 

 

 

 

 

Freq

0.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

 

 

BATTERY1 OF 4

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block

 

 

Voltage Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp

Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIS1

 

 

 

 

 

 

 

 

 

MBD

 

 

 

 

 

 

 

CB2

MODULE OUTPUT

 

A

B

C

 

L-L

0

0

0

V

L-N

0

0

0

V

I

0

0

0

A

KVA

0

0

0

%

KW

0

0

0

%

PF

0.0

0.0

0.0

 

KVA/KW

0/

0

 

Freq

 

0.0Hz

 

Rexfer Timeout

00:00

Legend

Inlet Air Temp 0°C

Load

Bypass Input—Displays the bypass input voltage and the bypass input frequency. The bypass cir- cuit breaker (BFB) is to the right of this block. The circuit breaker status is shown as open or closed.

UPS Input Power—Displays the UPS input voltage, current and frequency. The input circuit breaker (CB1) is to the right of this block. The circuit breaker status is shown as open or closed.

Battery Block—Displays the battery voltage and the charge or discharge current to or from the bat- tery. Pressing this icon switches among the connected battery strings. The Module Battery Discon- nect (MBD) is to the right of this block. The circuit breaker status is shown as open or closed.

DC Bus—Displays the DC Bus voltage and the state of the battery charger.

Load—Displays the output line voltage, phase voltage, current, kVA, kW, power factor and fre- quency. The critical load current per phase is also displayed in this block. During an overload, the time remaining before transfer is displayed at the bottom of the load box. After an overload transfer, retransfer timeout is displayed at the bottom of the load box.

6

Page 12
Image 12
Emerson 250-400kVA manual Mimic display