36

8

 

7

6

5

 

This document contains information proprietary to

 

 

FISCO

 

Rosemount Analytical, and is not to be made available

 

 

 

to those who may compete with Rosemount Analytical.

 

 

 

4

3

2

 

1

 

 

 

REVISION

D

MODEL 5081

 

THIS DOCUMENT IS

 

ATEX INTRINSIC SAFETY INSTALLATION

 

 

 

 

 

 

 

CERTIFIED BY

 

MODEL

 

 

 

 

Baseefa REV A

 

 

 

 

 

 

5081-T-FI

 

 

 

 

REV

 

XMTR

8

9

10

D

CONDUCTIVITY

7

REV

6

 

 

11

SENSORS

 

 

 

 

 

 

 

 

REV

222,225,226 & 228.

5

 

 

12

 

REV

242 (1" & 2" ONLY)

 

 

 

13

 

REV

 

4

 

 

 

 

 

 

 

 

 

REVISIONS NOT PERMITTED

 

3

 

 

14

 

W/O AGENCY APPROVAL

 

2

 

 

15

 

 

INFRARED

 

 

 

 

1

 

 

16

 

 

 

 

 

 

 

REMOTE CONTROL UNIT

 

 

 

 

 

(RMT PN 23572-00)

 

 

 

 

 

 

FOR USE IN

9

 

 

 

 

 

ZONE 0

 

 

 

HAZARDOUS AREA (ZONE 0)

1180

II1 G Baseefa03ATEX0399 EEx ia IIC T4

LTR

ECO

DESCRIPTION

BY

DATE

CHK

UNCLASSIFIED AREA

1400286

-T

C

9MAXIMUM SENSOR CABLE LENGTH IS 250 FEET.

8.PROCESS RESISTIVITY MUST BE LESS THAN 10 OHMS.

7.USE SUPPLY WIRES SUITABLE FOR 5^C ABOVE9 SURROUNDING AMBIENT.

6.ANY ASSOCIATED APPARATUS MUST BE ATEX APPROVED.

B5. CONTROL EQUIPMENT CONNECTED TO ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 250 Vrms OR Vdc.

4.ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.

3.THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS WITH ASSOCIATED APPARATUS WHEN THE FOLLOWING IS TRUE:

FIELD DEVICE INPUT

ASSOCIATED APPARATUS OUTPUT

Vmax OR Ui

Voc, Vt OR Uo;

Imax OR Ii

Isc, It OR Io;

Pmax OR Pi

Po;

Ci+ Ccable;

Ca, Ct OR Co

Li+ Lcable.

La, Lt OR Lo

2.RESISTANCE BETWEEN INTRINSICALLY SAFE GROUND AND EARTH GROUND MUST BE LESS THAN 1.0 Ohm.

1.INTRINSICALLY SAFE APPARATUS (MODEL 5081-T-FI, FIELDBUS TERMINATOR AND ANY ADDITIONAL FIELDBUS DEVICES) AND ASSOCIATED APPARATUS (SAFETY BARRIER) SHALL MEET THE FOLLOWING

AREQUIREMENTS: THE VOLTAGE (Vmax) AND CURRENT (Imax) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Vt) AND CURRENT (Isc OR It) WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS (SAFETY BARRIER). IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF THE INTRINSICALLY SAFE APPARATUS, INCLUDING INTERCONNECTING WIRING, MUST BE EQUAL OR LESS THAN THE CAPACITANCE (Ca) AND INDUCTANCE (La) WHICH CAN BE SAFELY CONNECTED TO THE APPARATUS. (REF. TABLE I).

NOTES: UNLESS OTHERWISE SPECIFIED

8

7

6

5

ATEX APPROVED

UNSPECIFIED

ASSOCIATED APPARATUS

POWER SUPPLY

SEE NOTE 3 AND TABLE 1

17.5 VDC MAX

WARNING- SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.

WARNING- TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES,

DISCONNECT POWER BEFORE SERVICING.

 

 

 

 

 

 

TABLE I

 

 

 

 

 

 

 

 

 

 

 

 

 

5081-T-FI ENTITY PARAMETERS

 

 

 

 

 

 

 

 

 

 

SUPPLY / SIGNAL TERMINALS TB1 15 AND 16

 

 

 

 

 

 

 

 

MODEL NO.

Vmax (Vdc)

 

Imax (mA)

 

 

Pmax (W)

Ci (uF)

 

Li (uH)

 

 

5081-T-FI

17.5

 

380

 

 

5.32

 

0

 

0

 

 

 

 

 

UNLESS OTHERWISE SPECIFIED

 

ITEM

PART NO.

 

 

 

DESCRIPTION

QTY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOLERANCES

 

 

 

 

 

 

BILL OF MATERIAL

 

 

 

 

 

.XX

-+ .030

ANGLES +- 1/2

 

 

 

 

 

 

 

 

 

 

 

.XXX

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- .010

 

 

APPROVALS

DATE

Uniloc

Rosemount Analytical,

 

 

 

 

 

 

DIMENSIONS ARE IN INCHES

 

 

 

 

 

 

 

 

 

 

 

Irvine, CA 92606

Baseefa Certified Product

 

 

REMOVE BURRS & SHARP EDGES .020 MAX

 

DRAWN

B. JOHNSON

5/3/04

TITLE

 

 

 

2400 Barranca Pkwy

No modifications permitted

 

 

NOMINAL SURFACE FINISH 125

 

 

 

 

 

 

 

 

 

 

MACHINED FILLET RADII .020 MAX

 

 

 

 

 

 

 

 

 

without the approval of

 

 

 

 

 

 

 

 

SCHEMATIC, INSTALLATION

the Authorized Person

 

MATERIAL

 

CHECKED J. FLOCK

5/6/04

Related Drawing

 

 

 

 

PROJECT

 

 

 

5081-T-FI XMTR

 

 

 

 

 

 

 

J. FLOCK

5/6/04

 

 

ATEX ZONE 0

 

 

 

 

 

 

 

 

ENGR APVD

 

 

 

 

 

 

 

 

FINISH

 

 

THIS DWG CREATED IN

 

D

DWG NO.

 

 

REV

5-6-04

8925

A

 

 

 

 

SOLID EDGE

 

 

1400286

A

 

 

 

 

 

 

 

SIZE

 

RELEASE DATE

ECO NO.

REV

 

 

3

 

 

 

2

SCALE NONE

 

TYPE

SHEET 1OF 1

4

 

 

 

 

 

 

 

 

 

 

 

 

10-96

 

 

 

 

 

 

 

 

 

 

 

 

1

C

B

A

SECTION 4.0 INTRINSICALLY SAFE & EXPLOSION PROOF

FIGURE 4-19. ATEX Intrinsically Safe Installation for Model 5081-T-FI

Page 42
Image 42
Emerson instruction manual Atex Intrinsically Safe Installation for Model 5081-T-FI