Instruction Manual

IB-106-300NH Rev. 4.2 July 2002

World Class 3000

NOTES

PROBE JUNCTION

BOX WIRING

 

 

CELL -VE

CELL +VE

CHROMEL

 

ALUMEL

 

 

 

 

}HEATER

 

 

GN

OR

YE

 

RD

 

 

GN

BK

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

5

 

6

7

 

8

 

BL

OR

 

YE

 

 

RD

 

 

GN

 

WH

 

BK

 

-

+

 

+

 

 

-

 

 

E

 

R

 

H

 

PROBE MV

PROBE MV

 

PROBE TC

 

 

PROBE TC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WORLD CLASS PROBE

1RELAY WIRE IS OPTIONAL, RELAY CAN BE BYPASSED WITH JUMPER JM-2 IF NOT WIRED TO THE IFT.

2STACK TC WIRING AS REQUIRED.

3ALL WIRES #16-#22 AWG TWISTED PAIR WITH SHIELD BY CUSTOMER EXCEPT AS NOTED.

STANDARD PROBE CABLE BETWEEN PROBE AND

4HPS BY ROSEMOUNT.

5REMOVE JM1 ON INTERCONNECT BOARD.

6REMOVE JM6 ON MICROPROCESSOR BOARD.

7IF RELAY WIRE OF NOTE 1 INSTALLED THEN REMOVE JM2 ON HPS 3000.

8IF STACK TEMPERATURE NOT USED.

9IF MPS 3000 NOT USED.

1 RELAY PER PROBE AVAILABLE FOR CALIBRATION

10STATUS INDICATION (48 V max, 100 mA max).

100 V.A.C. REQUIRES TRANSFORMER PART

11NUMBER 1M02961G02.

 

 

 

 

 

 

 

JUMPER JM7 INFORMATION APPEARS IN FIGURE 2-9.

 

 

 

 

 

 

 

 

ALWAYS DISCONNECT LINE VOLTAGE

 

 

 

 

 

 

JUMPER

 

 

FROM HEATER POWER SUPPLY

 

 

 

 

 

 

 

 

BEFORE CHANGING JUMPERS.

 

 

 

 

 

CONFIGURATION

 

 

 

 

 

 

 

 

 

LINE VOLTAGE

JUMPER

 

 

 

HEATER

ON

7

 

SELECTION

 

(INSTALL)

 

 

 

POWER

 

 

 

 

 

 

11

120 V.A.C./100 V.A.C.

JM4, JM1

 

 

 

REMOTE

REMOVE JM2

 

 

220/240 V.A.C.

JM5

 

 

 

ON

INSTALL JM2

1

 

 

 

 

 

 

 

 

 

 

 

PROBE HEATER

JUMPER

 

 

ELECTRONICS

JUMPER

 

 

VOLTAGE SECTION

(INSTALL)

 

 

 

SELECTION

 

 

 

 

 

 

 

 

WORLD CLASS PROBE

JM7

 

 

 

DIGITAL

REMOVE JM3, JM6

 

 

 

 

 

 

 

(NEXT GENERATION)

 

 

 

TOP

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

1

STACK

ANALOG

2 TWISTED PAIR SHIELDED

 

 

TRIAC

RELAY

 

 

TC

HEATER

#22 AWG BY CUSTOMER

 

J9 + -

+ -

+ -

 

 

WH

 

BK

(OPTIONAL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(INTERNAL

 

A

 

 

 

 

 

 

 

4

 

PROBE PROBE

 

WIRING)

 

 

 

MV

TC

AD590

BK WH

 

 

 

 

 

 

 

J8 + - + -

+ -

 

 

 

 

 

 

 

BOTTOM

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

PROBE

PROBE

 

 

 

 

 

 

 

 

MV

TC

 

 

 

 

4 TWISTED PAIR SHIELDED

 

J3 + -

+ -

 

 

 

 

OR CELL+

 

 

 

 

#22 AWG BY CUSTOMER

 

 

 

 

 

 

 

 

 

 

BL CELL -

 

 

 

 

 

 

 

 

 

 

YE HTR TC +

 

 

 

 

 

 

 

 

 

 

RD HTR TC -

 

 

 

 

 

 

 

 

 

 

WH

 

STACK

PROBE

 

 

 

 

 

 

BK

2

 

 

 

 

 

 

TC

HEATER

 

 

 

LINE

 

 

GN

J2 + -

R

H

J1

 

 

N L

 

 

 

 

 

LINE

 

GN/YE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

HPS 3000 INTERFACE MODULE

22540001

Figure 2-14. Wiring Layout for Complete IFT 3000 System with HPS (Sheet 1of 2)

2-18 Installation

Rosemount Analytical Inc. A Division of Emerson Process Management

Page 50
Image 50
Emerson B-106-300NH instruction manual J8 + +