Emerson B-106-300NH instruction manual CURRENT/VOLTAGE Selector Switch

Models: B-106-300NH

1 182
Download 182 pages 23.73 Kb
Page 51
Image 51

World Class 3000

Instruction Manual

IB-106-300NH Rev. 4.2 July 2002

CURRENT/VOLTAGE SELECTOR SWITCH

A

 

 

J1

 

3D39122G REV

 

 

 

 

POWER SUPPLY BOARD

 

 

 

ALWAYS DISCONNECT LINE VOLTAGE

 

 

 

FROM INTELLIGENT FIELD TRANSMITTER

 

 

 

BEFORE CHANGING JUMPERS.

 

 

 

 

 

 

 

JUMPER CONFIGURATION

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

VOLTAGE

JUMPER

 

PROBE HEATER

JUMPER

SECTION

(INSTALL)

 

VOLTAGE SECTION

(INSTALL)

100 V.A.C.

JM3, JM7, JM2

 

NOT USED

REMOVE

120 V.A.C.

JM8, JM7, JM1

 

 

 

JM9, JM10

 

 

 

 

200 V.A.C.

JM4, JM5, JM2

 

 

 

 

220 V.A.C.

JM6, JM5, JM2

 

 

 

 

240 V.A.C.

JM6, JM5, JM1

 

 

 

 

J5J6

NOT USED

L N E

LINE

VOLTAGE

3D39513G

MICROPROCESSOR

BOARD

CAL RET

NO GAS

LO GAS

HI GAS

IN CAL

SHIELD

RELAY –

RELAY +

SHIELD

AD590 –

AD590 +

SHIELD

TRIAC –

TRIAC +

J2

J3

J4

J5

J6

J7

J8

J9

JM7

I

V

JM6

J1

3D39120G REV

INTERCONNECT BOARD

SHIELD

STACK TC –

STACK TC +

SHIELD

PROBE TC –

PROBE TC +

SHIELD

PROBE MV –

PROBE MV +

JM1

2

B

INTELLIGENT FIELD

TRANSMITTER IFT 30005 CONDUCTOR SHIELDED CABLE PER PROBE #16 AWG BY CUSTOMER

 

 

PROBE 1

 

 

PROBE 2

 

 

PROBE 3

 

 

 

 

PROBE 4

 

 

 

 

LINE OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE IN

 

L

GAS

CAL

RET

GAS

GAS

GAS

CAL

RET

GAS

GAS

GAS

CAL

RET

GAS

 

GAS

 

GAS

CAL

RET

GAS

GAS

 

L

L

 

 

 

 

 

 

 

HI

IN

CAL

NO

LOW

HI

IN

CAL

NO

LOW

HI

IN

CAL

NO

 

LOW

 

HI

PROBE4INSOLENOID

CAL

HIGHGAS SOLENOIDNO

LOWLOWGAS

 

 

E

 

 

 

 

 

 

N

PROBE1 SOLENOID

PROBE2

SOLENOID

PROBE3 SOLENOID

SOLENOID

N

N

J10

PRESSURE SWITCH

 

 

 

 

NC C NO

NC C NO

NC C NO

NC C NO

 

 

J13

J14

J15

J16

 

J17

J18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBE 1

PROBE 2

PROBE 3

 

PROBE 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPS TERMINATION BOARD

MPS 3000 MULTIPROBE CALIBRATION GAS SEQUENCER (OPTIONAL)

LINE VOLTAGE

27270012

Figure 2-14. Wiring Layout for Complete IFT 3000 System with HPS (Sheet 2 of 2)

Rosemount Analytical Inc. A Division of Emerson Process Management

Installation 2-19

Page 51
Image 51
Emerson B-106-300NH instruction manual CURRENT/VOLTAGE Selector Switch