World Class 3000
Instruction Manual
SECTION 5
GENERAL USER INTERFACE (GUI) OPERATION
5-1 OVERVIEW
Ensure that the oxygen analyzer, heater power supply, and intelligent field transmitter have been properly connected. It is important to check that grounding and screening of termina- tions are correctly made to prevent the introduc- tion of ground loops. The IFT is equipped with noise suppression circuitry on the power supply and signal input lines. Proper grounding at in- stallation will ensure accuracy of function.
The following five languages are can be se- lected within the IFT:
English Italian
French Spanish
German
NOTE
Support the keypad with the free hand to prevent bounce back of the IFT door.
a.Intelligent Field Transmitter (IFT)
The Intelligent Field Transmitter may be supplied with either of two configurations. These are the blind version and the deluxe version. The two versions differ as follows:
1.Blind Version. The blind version has no display and no keypad. With this version an external HART communica- tions device is required.
2.Deluxe Version (GUI). The deluxe version is also known as the General User Interface (GUI) version. This IFT contains an LED display, liquid crystal display panel, and an
b.HART Communicator Interface Devices
The HART communications protocol can interface with any of the above IFT ver- sions. To interface a HART communicator with an IFT, one of three interface devices is required. The interface devices are as follows:
1.Rosemount Model 275 Handheld Communicator. The handheld com- municator requires Device Descriptor (DD) software specific to the World Class 3000 product. The DD software
will be supplied with many model 275 units, but can also be programmed into
existing units at most Fisher-5 Rosemount service offices.
2.Personal Computer (PC). The use of a personal computer requires Corner- stone software with Module Library (ModLib) specific to the World Class 3000 product.
3.Selected Distributed Control Systems. The use of distributed control systems requires input/output (I/O) hardware and software which permit HART communications.
This section of the manual deals with op- erator controls and displays available with the GUI equipped IFT. Operating parame- ters are listed and instructions are included for viewing and changing them.
Any procedures not associated with normal operation are included in Section 2, Instal- lation, or Section 5, Troubleshooting.
Rosemount Analytical Inc. A Division of Emerson Process Management | General User Interface (GUI) Operation |