MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B)
Safety Notes
130
Data Loss
Exchanging the battery always results in data loss of the devices which use the battery as
power backup.
Back up affected data before exchanging the battery.
Data Loss
Installing another battery type than the one that is mounted at product delivery may cause
data loss since other battery types may be specified for other environments or may have a
shorter lifetime.
Only use the same type of lithium battery as is already installed.
PCB and Battery Holder Damage
Removing the battery with a screw driver may damage the PCB or the battery holder.
Do not use a screw driver to remove the battery from its holder.
Product Damage
Incorrect replacement of lithium batteries can result in a hazardous explosion.
When exchanging the on-board lithium battery, make sure that the new and the old battery
are exactly the same battery models.
If the respective battery model is not available, contact your local Emerson sales
representative for the availability of alternative officially approved battery models.
Product Damage
The insulator is installed in order to prevent accidental shorting to the battery, which is
installed positive side up.
Do not remove the battery holder insulator.
Product Damage
It is especially important that the insulator remains intact and that the battery holder
maintains a low profile if a PMC or a SATA drive is installed in the PMC site 2 location. Otherwise
a PMC or SATA drive will not fit.
Do not deform the battery holder retaining tab during the battery exchange procedure so that
the battery holder retaining tab continues to perform its function and so that the battery
holder maintains a low profile.