The following table lists all of the editable parameters that are available on the component data table. The standard values for these parameters were taken from the second editions of the Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids and the Compressibility Factors of Natural Gas and Other Related Hydrocarbon Gases.

Parameter

Description

 

 

Component

This drop-down list contains the complete catalog of available components

 

for the selected stream.

Usr Std

Indicates the source of the component:

 

Usr - The component was edited or defined by the user.

 

Std - The component was selected from the standard list of components

 

 

and no changes were made to its standard data.

Det #

The component’s detector number.

 

 

Ret Time

Time in seconds before the apex of the component's peak will appear. The

 

rentention time can be set from 0 to 3600 seconds.

 

CAUTION: Ensure that the component retention times do not exceed the

 

analysis time, as defined by the Timed Events table. MON 20/20 does not

 

automatically prevent the user from defining excessive component

 

retention times.

Resp Fact

A component’s response factor is equal to the raw data of the component's

 

peak divided by the component's concentration.

 

The maximum value is 1.0E+38.

 

 

Calib Type

MON 20/20 can perform four types of calibrations:

 

Single-Level- Uses the standard calibration in which the response

 

 

factor is needed to determine the mole percentage during the calibra-

 

 

tion.

 

Fixed - During the calibration, the response factor is not updated.

 

Relative - Calibration in which a reference component is used to

 

 

compute the mole percentage.

 

Multi-Level- Uses a polynomial equation to compute the mole percent-

 

 

age during the calibration. Values must be entered in the Mult-level

 

 

Calib 'a', Mult-level Calib 'b', Mult-level Calib 'c', and Mult-level Calib

 

 

'd' cells. See “Multi-level calibration” on page B-13for more informa-

 

 

tion.

Calib Conc

The amount, in mole percent, parts per million (ppm) or parts per billion

 

(ppb), of the component that is present in the calibration gas.

Unit

Indicates the unit of measure used when calculating and displaying the

 

component’s calibration concentration. Options are Mole%, ppm and

 

ppb.

 

 

 

4-7

Page 160
Image 160
Emerson Process Management 3-9000-745 manual Parameter Description

3-9000-745 specifications

Emerson Process Management is a leading provider of automation solutions, offering a range of products designed to streamline operations and enhance productivity in various industrial sectors. One of their notable offerings is the 3-9000-745 model, a versatile and robust device that exemplifies Emerson's commitment to innovation and efficiency.

The 3-9000-745 is primarily known for its application in process control and monitoring. It is engineered to manage operations in dynamic environments where real-time data is critical. This device features advanced control algorithms that allow for precise regulation of processes, ensuring optimal performance and minimal downtime. Its reliability makes it ideal for industries such as oil and gas, chemicals, water treatment, and manufacturing.

One of the key technologies integrated into the 3-9000-745 is advanced analytics. This technology leverages data collected from various sensors and devices to provide insightful analysis regarding operational efficiency. With this capability, users can make informed decisions and forecast maintenance needs, thus reducing operational costs and improving productivity.

The communication capabilities of the 3-9000-745 are also noteworthy. It supports multiple communication protocols, which allows for seamless integration with existing systems, enhancing interoperability within a facility. This feature is particularly beneficial for organizations looking to modernize their infrastructure without overhauling their entire process control system.

In terms of user interface, the 3-9000-745 is designed with ease of use in mind. It includes a user-friendly interface that simplifies configuration and monitoring processes. The intuitive dashboard provides real-time insights and alerts, allowing operators to respond swiftly to any anomalies detected in the system.

Durability and ruggedness are additional characteristics that set the 3-9000-745 apart. Designed for harsh industrial environments, it meets stringent safety and regulatory standards, ensuring reliable operation even in challenging conditions. This reliability contributes to minimized downtime, maximizing productivity and efficiency.

In conclusion, the Emerson Process Management 3-9000-745 stands out as a comprehensive solution for process control and monitoring. With its advanced analytics, robust communication capabilities, user-friendly interface, and durability, it effectively addresses the diverse needs of modern industries, contributing to greater operational efficiency and sustainability.