User Manual

MON20/20 Software for Gas Chromatographs

3-9000-745

OCTOBER 2010

 

 

Table C-6 SIM_2251 Modbus register list (floating point)

 

Reg. No.

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7092

 

Compressibilty (Last Calibration)

 

 

 

 

 

 

 

 

 

 

 

7093

 

Total GPM (Last Calibration)

 

 

 

 

 

 

 

 

 

 

 

 

7094

 

Total Unnormalized (Last Calibration)

 

 

 

 

 

 

 

 

 

 

 

7095-7110

Response Factors (#1-16), Component Table n (where n equals the CDT # used during

 

 

 

 

the last run)

 

 

 

 

 

 

7111-7126

Response Factors (#1-16), Component Table n (where n equals the CDT # used during

 

 

 

 

the last run)

 

 

 

 

 

 

7127-7162

Averages, User-define 1-36

 

 

 

 

 

Note: Registers 7127-7141 are copies of registers 7055-7069.

 

 

 

 

 

 

 

 

 

 

 

7163-7198

Maximum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7199-7234

Minimum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7235-7270

First (most recent) archive of averages, User-define 1-36

 

 

 

 

Note: Registers 7235-7249 are copies of registers 7070-7084.

 

 

 

 

 

 

 

 

 

 

 

7271-7306

First (most recent) archive of maximum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7307-7342

First (most recent) archive of minimum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7343-7378

Second archive of averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7379-7414

Second archive of maximum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7415-7450

Second archive of minimum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7451-7486

Third (oldest) archive of averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7487-7522

Third (oldest) archive of maximum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

7523-7558

Third (oldest) archive of minimum values from averages, User-define 1-36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-7 SIM_2251 Modbus Communication Indices

 

 

 

 

 

 

 

Description: RW = read/write (1) or read-only (0)

 

 

Reg.

 

 

LEN = length

 

 

 

 

No.

 

 

REGS = number of Modbus registers required

 

 

 

 

 

 

 

 

 

 

 

 

RW

 

TYPE

LEN

 

REGS

VARIABLE NAME, POINTER, OR DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

9001

0

 

string

6

 

3

device model number

 

 

 

 

 

 

 

 

 

 

 

 

9004

0

 

string

4

 

2

software revision

 

 

 

 

 

 

 

 

 

 

 

 

9006

1

 

integer

2

 

1

system time month (1-12)

 

 

 

 

 

 

 

 

 

 

 

 

9007

1

 

integer

2

 

1

system time day (1-31)

 

 

 

 

 

 

 

 

 

 

 

 

9008

1

 

integer

2

 

1

system time year (0-99)

 

 

 

 

 

 

 

 

 

 

 

C-14

Page 433
Image 433
Emerson Process Management 3-9000-745 manual Reg

3-9000-745 specifications

Emerson Process Management is a leading provider of automation solutions, offering a range of products designed to streamline operations and enhance productivity in various industrial sectors. One of their notable offerings is the 3-9000-745 model, a versatile and robust device that exemplifies Emerson's commitment to innovation and efficiency.

The 3-9000-745 is primarily known for its application in process control and monitoring. It is engineered to manage operations in dynamic environments where real-time data is critical. This device features advanced control algorithms that allow for precise regulation of processes, ensuring optimal performance and minimal downtime. Its reliability makes it ideal for industries such as oil and gas, chemicals, water treatment, and manufacturing.

One of the key technologies integrated into the 3-9000-745 is advanced analytics. This technology leverages data collected from various sensors and devices to provide insightful analysis regarding operational efficiency. With this capability, users can make informed decisions and forecast maintenance needs, thus reducing operational costs and improving productivity.

The communication capabilities of the 3-9000-745 are also noteworthy. It supports multiple communication protocols, which allows for seamless integration with existing systems, enhancing interoperability within a facility. This feature is particularly beneficial for organizations looking to modernize their infrastructure without overhauling their entire process control system.

In terms of user interface, the 3-9000-745 is designed with ease of use in mind. It includes a user-friendly interface that simplifies configuration and monitoring processes. The intuitive dashboard provides real-time insights and alerts, allowing operators to respond swiftly to any anomalies detected in the system.

Durability and ruggedness are additional characteristics that set the 3-9000-745 apart. Designed for harsh industrial environments, it meets stringent safety and regulatory standards, ensuring reliable operation even in challenging conditions. This reliability contributes to minimized downtime, maximizing productivity and efficiency.

In conclusion, the Emerson Process Management 3-9000-745 stands out as a comprehensive solution for process control and monitoring. With its advanced analytics, robust communication capabilities, user-friendly interface, and durability, it effectively addresses the diverse needs of modern industries, contributing to greater operational efficiency and sustainability.