Component Data Table

OCTOBER 2010

Table A-1 Example Standard Component Data Table (Continued)

 

 

 

 

 

 

 

 

 

 

Daniel Sim

 

Mol

Reid

Rel Dens

Rel Dens

 

 

Gross Dry

Net Dry

AGA 8

2251 I.D.

Component Name

Wt

Vapor

Gas

Liquid

Lb/Gal

GPM Factor

BTU

BTU

Component

No.

 

 

 

 

 

 

 

 

 

 

 

i-Propylbenzene

120.19

0.188

4.1498

0.8663

7.223

0.4396

5976.6

5674

n-Nonane

*

 

 

 

 

 

 

 

 

 

 

 

i-Octane

114.23

1.708

3.9439

0.6962

5.804

0.5199

6246.1

5792.2

n-Octane

*

 

 

 

 

 

 

 

 

 

 

 

Methane

16.0425

5000

0.5539

0.3

2.5

0.169487

1012.34

911.5

Methane

00

 

 

 

 

 

 

 

 

 

 

 

Methyl Alcohol

32.04

4.63

1.1063

0.796

6.64

0.1275

868.7

767.9

None

*

 

 

 

 

 

 

 

 

 

 

 

Methylcyclo C5

84.16

4.503

2.9057

0.7536

6.283

0.3538

4511.6

4209.1

n-Hexane

*

 

 

 

 

 

 

 

 

 

 

 

Methylcyclo C6

98.19

1.609

3.39

0.774

6.453

0.4019

5228

4874.9

n-Heptane

*

 

 

 

 

 

 

 

 

 

 

 

2-Methylhexane

100.21

2.271

3.4596

0.683

5.694

0.4647

5507.3

5104

n-Heptane

*

 

 

 

 

 

 

 

 

 

 

 

3-Methylhexane

100.21

2.13

3.4596

0.6917

5.767

0.4589

5511.3

5107.8

n-Heptane

*

 

 

 

 

 

 

 

 

 

 

 

m-Xylene

106.17

0.326

3.6655

0.8687

7.243

0.3871

5219.9

4967.8

n-Octane

*

 

 

 

 

 

 

 

 

 

 

 

n-Butane

58.1222

51.567

2.0068

0.5842

4.8706

0.315183

3269.85

3017.97

n-Butane

04

 

 

 

 

 

 

 

 

 

 

 

n-Decane

142.2817

0.06148

4.9126

0.73458

6.1244

0.613636

7760.81

7206.63

n-Decane

*

 

 

 

 

 

 

 

 

 

 

 

n-Heptane

100.2019

1.619

3.4597

0.68823

5.7379

0.461258

5515.33

5111.8

n-Heptane

45

 

 

 

 

 

 

 

 

 

 

 

n-Hexane

86.1754

4.961

2.9754

0.66406

5.5364

0.411121

4766.9

4414.19

n-Hexane

39

 

 

 

 

 

 

 

 

 

 

 

n-Nonane

128.2551

0.1809

4.4283

0.72224

6.0215

0.562592

7012.49

6508.02

n-Nonane

38

 

 

 

 

 

 

 

 

 

 

 

n-Octane

114.2285

0.5349

3.944

0.70655

5.8907

0.512168

6263.46

5809.41

n-Octane

20

 

 

 

 

 

 

 

 

 

 

 

n-Pentane

72.1488

15.576

2.4911

0.63071

5.2584

0.362396

4017.97

3715.58

n-Pentane

06

 

 

 

 

 

 

 

 

 

 

 

Neohexane

86.18

9.856

2.9753

0.654

5.453

0.4175

4747.2

4394.1

n-Hexane

*

 

 

 

 

 

 

 

 

 

 

 

Neopentane

72.15

35.9

2.4911

0.5967

4.975

0.383

3993.9

3691.4

i-Pentane

07

 

 

 

 

 

 

 

 

 

 

 

Nitrogen

28.0134

0

0.9672

0.80687

6.7271

0.10999

0

0

Nitrogen

14

 

 

 

 

 

 

 

 

 

 

 

NO2

46

0

0

0

0

0

0

0

None

19

 

 

 

 

 

 

 

 

 

 

 

NO

30.01

0

0

0

0

0

0

0

None

*

 

 

 

 

 

 

 

 

 

 

 

N2O

44.02

0

0

0

0

0

0

0

None

18

 

 

 

 

 

 

 

 

 

 

 

A-4

MON 20/20 Software for Gas Chromatographs

Page 399
Image 399
Emerson Process Management 3-9000-745 manual NO2

3-9000-745 specifications

Emerson Process Management is a leading provider of automation solutions, offering a range of products designed to streamline operations and enhance productivity in various industrial sectors. One of their notable offerings is the 3-9000-745 model, a versatile and robust device that exemplifies Emerson's commitment to innovation and efficiency.

The 3-9000-745 is primarily known for its application in process control and monitoring. It is engineered to manage operations in dynamic environments where real-time data is critical. This device features advanced control algorithms that allow for precise regulation of processes, ensuring optimal performance and minimal downtime. Its reliability makes it ideal for industries such as oil and gas, chemicals, water treatment, and manufacturing.

One of the key technologies integrated into the 3-9000-745 is advanced analytics. This technology leverages data collected from various sensors and devices to provide insightful analysis regarding operational efficiency. With this capability, users can make informed decisions and forecast maintenance needs, thus reducing operational costs and improving productivity.

The communication capabilities of the 3-9000-745 are also noteworthy. It supports multiple communication protocols, which allows for seamless integration with existing systems, enhancing interoperability within a facility. This feature is particularly beneficial for organizations looking to modernize their infrastructure without overhauling their entire process control system.

In terms of user interface, the 3-9000-745 is designed with ease of use in mind. It includes a user-friendly interface that simplifies configuration and monitoring processes. The intuitive dashboard provides real-time insights and alerts, allowing operators to respond swiftly to any anomalies detected in the system.

Durability and ruggedness are additional characteristics that set the 3-9000-745 apart. Designed for harsh industrial environments, it meets stringent safety and regulatory standards, ensuring reliable operation even in challenging conditions. This reliability contributes to minimized downtime, maximizing productivity and efficiency.

In conclusion, the Emerson Process Management 3-9000-745 stands out as a comprehensive solution for process control and monitoring. With its advanced analytics, robust communication capabilities, user-friendly interface, and durability, it effectively addresses the diverse needs of modern industries, contributing to greater operational efficiency and sustainability.