Confidential
EPSON
TITLE SHEET
REVISION NO
SHEETNEXT
90 91
A
TM-T81 Specification (STANDARD)
[Notes] When <Function 082 or 182> is transmitted, the data followi ng m ust not be
transmitted until the status is receiv ed.
[Reference] Appendix H, Appendix I
<Function 065> GS ( k pL pH cn fn n (cn = 48 , fn = 65)
[Name] PDF417: Set the number of columns in the data region
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B pL pH cn fn n
Decimal 29 40 107 pL pH cn fn n
[Range] (pL + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 65
0 n 30
[Default] n = 0
[Description] Sets the num ber of columns in the data region for P DF 417.
When n = 0, specifies automatic pr oc essing. In this case, the num ber of columns in
the data region is calculated with the number of codewords or the range of print area.
When n 0, sets the number of columns in the dat a region to n codewords.
[Notes] The following data are not i ncluded in the number of columns.
Start pattern and stop pattern
Left-row indicator codewords and right-row indicator codewords
<Function 066> GS ( k pL pH cn fn n (cn = 48 , fn = 66)
[Name] PDF417: Set the number of rows
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B pL pH cn fn n
Decimal 29 40 107 pL pH cn fn n
[Range] (pL + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 66
n = 0 , 3 n 90
[Default] n = 0
[Description] Sets the num ber of rows for PDF417.
When n = 0, specifies automatic pr oc essing. In this case, the num ber of rows is
calculated with the number of codewords or the range of pr i nt area.
When n 0, sets the number of rows to n rows.