Confidential
EPSON
TITLE SHEET
REVISION NO
SHEETNEXT
14 13
TM-T81
Specification
(STANDARD) A
Table 2.1.1 TM-T81 Printer Status and Signals (Continued)
Pin
number Signal
name Signal
direction Function
2) When XON/ XOFF control is selected:
The signal indicates whether the printer is correctly connected and is
ready to receive data. SPACE indicates that the printer is ready to
receive data. The signal is always SPACE except in the f ollowing
cases:
During the period f rom when the power is t urned on to when the
printer is ready to receive data
During t he self-test
25 INIT Input Changing the DIP switch setting enables this signal to be used as a
reset signal for the printer.
The printer is reset when the signal remains SPACE for 1 ms or more.
*1 Definition of “receive buff er full”
When the receive buffer capac i ty is specified to 4 KB (DIP SW1-2 is Off):
If the DIP SW 2- 5 is off , when the remai ni ng space in t he recei v e buffer drops to 128 bytes,
the printer status becomes “buffer ful l” and it remai ns “buffer ful l” until t he space in the
receive buffer increases to 256 bytes.
If the DIP SW 2- 5 is on, when the rem ai ning space i n the r ecei v e buf fer drops to 128 bytes,
the printer status becomes “buffer ful l” and it remai ns “buffer ful l” until t he space in the
receive buffer increases to 138 bytes.
When the receive buffer capac i ty is specified to 45 bytes (DIP SW1-2 is On):
Regardless of the DIP SW2-5 setting, when the remaining space in the rec eive buffer
drops to 16 bytes, the printer status becomes “buffer f ull” and it remains “buff er ful l” until
the space in the receive buffer i ncreases to 26 bytes.
The printer i gnores the data received when the remaining space in the receive buff er
is 0 bytes.
2.1.1.4 XON/XOFF transmit timin g
When XON/XOFF control i s selected, the printer transmits XON or XOFF signals as foll ows.
Transmit timing diff ers depending on the DIP SW2-1 setting.
Table 2.1.2 XON/XOFF Transmit Timing
DIP SW 2-1 status
Printer status ON OFF
XON
transmission
When the pri nter goes online after turning on the power (or
reset using interface) Transmit Transmit
When the rec ei ve buffer is released from the buffer f ul l state Transmi t Transmit
When the pri nter switches from offline to online — Transmit
When the pri nter recovers from an error using the
DLE ENQ 1 or DLE ENQ 2 commands — Transmit
When the rec ei ve buffer becomes full Transmit Transmit
XOFF
Transmission When the printer switches from onli ne to offline — Transmit
NOTES: 1. The XON code is <11>H and the XOFF code is <13>H.
2. In case , XON is not transmitted when the receive buff er is full.
3. In case , XOFF is not transmitted when the receive buf fer is full.