Confidential

GS ( A pL pH n m

[Name]

Execute test print

 

 

 

 

 

 

[Format]

ASCII

GS

(

A

pL

pH

n

m

 

Hex

1D

28

41

pL

pH

n

m

 

Decimal

29

40

65

pL

pH

n

m

[Range]

(pL + pH 256) = 2

(pL = 2 , pH = 0)

 

 

 

0 n 2 , 48 n 50

 

 

 

 

 

1 m 3 , 49 m 51

 

 

 

 

[Description]

Executes a specified test print.

 

 

 

 

 

pL, pH specify (pL + pH 256) as the number of bytes after pH (n and m).

 

 

n specifies the paper used for the test print.

 

 

n

 

Paper source

 

 

 

 

 

 

0, 48

Basic sheet (roll paper)

 

 

 

 

 

1, 49

Roll paper

 

 

 

 

 

 

2, 50

 

 

 

 

 

 

 

m specifies a test pattern.

m

Test pattern

1, 49

Hexadecimal dump print

2, 50

Printer status print

3, 51

Rolling pattern print

[Notes] The printer executes a software reset after processing this command.

Clears the receive and print buffers.

Resets all setting values in RAM (the print area, the character styles, and others) that were in effect at power on. (The data in the NV memory are not reset.)

 