Confidential

<Function 12> GS ( E pL pH fn a

(fn = 12)

 

 

 

[Name]

Transmit the configuration item for the serial interface

[Format]

ASCII

GS

(

E

pL

pH

fn

a

 

Hex

1D

28

45

pL

pH

fn

a

 

Decimal

29

40

69

pL

pH

fn

a

[Range]

(pL + pH 256) = 2 (pL = 2 , pH = 0)

 

 

 

fn = 12

 

 

 

 

 

 

 

 

a = 1

 

 

 

 

 

 

 

[Description] Transmits the configuration item for the serial interface specified by a.

aConfiguration item

1 Transmission speed

GS ( H pL pH fn [parameters]

[Name]

Request transmission of response or status

[Description]

Various processes are performed for the response.

pL, pH specify (pL + pH 256) as the number of bytes after pH (fn and [parameters]).

fn specifies the function.

[parameters] specify the process of each function.

 

fn

 

Format

Function

Function name

 

 

No.

 

48

 

GS ( H pL pH fn m d1 d2 d3 d4

48

Set the process ID response.

[Note]

Do not use this command in a system that uses the printer with the OPOS driver or

 

 

the JavaPOS driver provided by Seiko Epson Corporation.

<Function 48> GS ( H pL pH fn m d1 d2 d3 d4

(fn = 48)

 

 

 

[Name]

Set the process ID response

 

 

 

 

 

 

 

 

[Format]

ASCII

GS

(

H

pL

pH

fn

m

d1

d2

d3

d4

 

Hex

1D

28

48

pL

pH

fn

m

d1

d2

d3

d4

 

Decimal

29

40

72

pL

pH

fn

m

d1

d2

d3

d4

[Range]

(pL + pH 256) = 6

(pL =6 , pH = 0)

 

 

 

 

 

 

 

 

fn = 48

 

 

 

 

 

 

 

 

 

 

 

 

m = 48

 

 

 

 

 

 

 

 

 

 

 

 

32 d 126

 

 

 

 

 

 

 

 

 

 

[Description]

Saves the process ID specified by (d1, d2, d3, d4) for the data processed just before

 

this function.

 

 

 

 

 

 

 

 

 

 

 

TITLE

SHEET

NO

 

EPSON

TM-T81

REVISION

 

 

A

 

 

 

 

 

 

 

Specification

 

 

 

 

 

NEXT

SHEET

 

(STANDARD)

 

82

81

 

 

 

 

 

Page 91
Image 91
Epson T81 Function 12 GS E p L p H fn a Fn =, GS H pL pH fn parameters, Function 48 GS H p L p H fn m d1 d2 d3 d4