![](/images/backgrounds/156065/bg45.png)
Confidential
EPSON
TITLE SHEET
REVISION NO
SHEETNEXT
59 60
A
DLE DC4 fn a b (fn = 2)
[Name] Execute power-off sequence
[Format] ASCII DLE DC4 fn a b
Hex 10 14 fn a b
Decimal 16 20 fn a b
[Range] fn = 2
a = 1
b = 8
[Description] • Ex ec ut es the printer power-off sequence and transmits the power-off notice.
• Stores the values of the maintenance count er.
• Sets the interface to BUSY.
• Sets the printer to standby mode.
[Notes] • Take the f ol lowing into consideration:
• If the received data includes a data str i ng matching this command, the pri nt er
performs the command. Users must consider this.
For example: Gr aphi c data might accidentally inc l ude a data string matching this
command.
• Do not embed this command within another com m and.
For example: Gr aphi c data might include this comm and.
• This command does not shut the power off . The operator m ust turn off the power
after receiving the power-off notice.
• If this command i s encountered, the printer will not continue to process anything. To
recover the printer to print again, it is necessary to turn the power on again or execute
a hardware reset.
[Reference] Appendix G