Confidential

<Function 069> GS ( k pL pH cn fn m n

(cn = 48 , fn = 69)

[Name]

PDF417: Set the error correction level

 

 

 

 

[Format]

ASCII

GS

(

k

pL

pH

cn

fn

m

n

 

Hex

1D

28

6B

pL

pH

cn

fn

m

n

 

Decimal

29

40

107

pL

pH

cn

fn

m

n

[Range]

(pL + pH 256) = 4

(pL = 4 , pH = 0)

 

 

 

 

 

cn = 48

 

 

 

 

 

 

 

 

 

 

fn = 69

 

 

 

 

 

 

 

 

 

 

m = 48, 49

 

 

 

 

 

 

 

 

 

48 n 56 [when m = 48]

 

 

 

 

 

 

 

1 n 40 [when m = 49]

 

 

 

 

 

 

[Default]

m = 49 ,

n = 1

 

 

 

 

 

 

 

 

[Description]

Sets the error correction level for PDF417.

 

 

 

When m = 48, the error correction level is set by the “Level Setting” and the “Ratio Setting” is canceled. The number of error correction codewords are as follows:

n

Function

Number of error correction codewords

48

Select error correction level 0

2

49

Select error correction level 1

4

50

Select error correction level 2

8

51

Select error correction level 3

16

52

Select error correction level 4

32

53

Select error correction level 5

64

54

Select error correction level 6

128

55

Select error correction level 7

256

56

Select error correction level 8

512

When m = 49, the error correction level is set by the “Ratio Setting” to the level indicated by the number for encoded data, and the “Level Setting” is canceled. The rate is set to [n 10%]. The error correction levels in the following table are determined by the calculation [Data codeword n 0.1 = (A)] (fractions of 0.5 and over are rounded up, and others are truncated.)

Result (A)

Use the error correction level

Number of error correction codeword

0 to 3

Error correction level 1

4

4 to 10

Error correction level 2

8

11 to 20

Error correction level 3

16

21 to 45

Error correction level 4

32

46 to 100

Error correction level 5

64

101 to 200

Error correction level 6

128

201 to 400

Error correction level 7

256

401 or more

Error correction level 8

512

 

TITLE

SHEET

NO

 

EPSON

TM-T81

REVISION

 

 

A

 

 

 

 

 

 

 

Specification

 

 

 

 

 

NEXT

SHEET

 

(STANDARD)

 

93

92

 

 

 

 

 

Page 102
Image 102
Epson T81 specifications Function 069 GS k p L p H cn fn m n Cn = 48 , fn =