Confidential
EPSON
TITLE SHEET
REVISION NO
SHEETNEXT
91 92
A
TM-T81 Specification (STANDARD)
<Function 067> GS ( k pL pH cn fn n (cn = 48 , fn = 67)
[Name] PDF417: Set the width of the module
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B pL pH cn fn n
Decimal 29 40 107 pL pH cn fn n
[Range] (pL + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 67
2 n 8
[Default] n = 3
[Description] Sets the widt h of the module for PDF417 to n dots.
<Function 068> GS ( k pL pH cn fn n (cn = 48 , fn = 68)
[Name] PDF417: Set the row height
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B pL pH cn fn n
Decimal 29 40 107 pL pH cn fn n
[Range] (pL + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 68
2 n 8
[Default] n = 3
[Description] Sets the row height for PDF417 to [n × (the width of the modul e)].