GS g 2 m nL nH

[Name]

Transmit maintenance counter

 

[Format]

ASCII

GS

g

2

m nL nH

 

 

Hex

1D

67

32

m nL nH

 

 

Decimal

29

103 50

m nL nH

 

[Range]

m = 0

 

 

 

 

 

 

 

 

(nL + nH 256) = 20, 21, 50, 70, 148, 149, 178, 198

 

 

(nL = 20, 21, 50, 70, 148, 149, 178, 198 , nH = 0)

 

[Description]

Transmits the value of the maintenance counter specified by (nL + nH 256).

 

(nL + nH 256)

 

 

 

 

 

 

 

Hex

Decimal

 

 

Maintenance counter [Units]

Kind of counter

 

14

20

 

 

Number of line feeds. [Lines]

Resettable

 

15

21

 

 

Number of times head is energized. [Times]

(can be reset)

 

32

50

 

 

Number of autocutter operations. [Times].

 

 

46

70

 

 

Printer operation time. [Hours].

 

 

 

 

 

 

 

 

 

 

94

148

 

 

Number of line feeds. [Lines]

 

Cumulative

 

95

149

 

 

Number of times head is energized. [Times]

 

 

 

B2

178

 

 

Number of autocutter operations. [Times].

 

 

 

C6

198

 

 

Printer operation time. [Hours].

 

 

[Notes] The maintenance counter values are measurements; therefore, their values will be affected by the timing of errors and how and when the power is turned off.

When this command is transmitted, the data following must not be transmitted until the status is received.

[Reference] Appendix G

GS h n

[Name]

Set bar code height

 

[Format]

ASCII

GS

h

n

 

Hex

1D

68

n

 

Decimal

29

104

n

[Range]

1

n 255

 

 

 

[Default]

n

= 162

 

 

 

[Description]

Sets the height of the bar code to n dots.

 