Confidential

GS ( K pL pH fn [parameters]

[Name]

Select print control method(s)

[Description]

Selects the print control methods.

pL, pH specify (pL + pH 256) as the number of bytes after pH (fn and [parameters]).

fn specifies the function.

[parameters] specify the process of each function.

fn

Format

Function No.

Function name

50

GS ( K pL pH fn m

50

Select the print speed.

<Function 50> GS ( K pL pH fn m

(fn = 50)

 

 

 

[Name]

Select the print speed

 

 

 

 

 

[Format]

ASCII

GS

(

K

pL

pH

fn

m

 

Hex

1D

28

4B

pL

pH

fn

m

 

Decimal

29

40

75

pL

pH

fn

m

[Range]

(pL + pH 256) = 2 (pL = 2

, pH = 0)

 

 

 

fn = 50

 

 

 

 

 

 

 

 

0 m 9 , 48 m 57

 

 

 

 

 

[Default]

m = 0 (setting values of GS ( E <Function 5: a = 6>)

[Description] Selects the print speed.

m

Print speed

 

0, 48

Setting values of GS ( E <Function 5: a = 6>.

 

1, 49

Print speed level 1.

slow

2, 50

Print speed level 2.

3, 51

Print speed level 3.

4, 52

Print speed level 4.

5, 53

Print speed level 5.

6, 54

Print speed level 6.

7, 55

Print speed level 7.

8, 56

Print speed level 8.

9, 57

Print speed level 9.

fast

 

TITLE

SHEET

NO

 

EPSON

TM-T81

REVISION

 

 

A

 

 

 

 

 

 

 

Specification

 

 

 

 

 

NEXT

SHEET

 

(STANDARD)

 

83

82

 

 

 

 

 

Page 92