Confidential

GS ( D pL pH m [a1 b1]...[ak bk]

[Name]

Enable/disable real-time command

 

 

 

 

 

[Format]

ASCII

GS

(

D

pL

pH

m

[ a1

b1 ]...[ ak

bk ]

 

Hex

1D

28

44

pL

pH

m

[ a1

b1 ]...[ ak

bk ]

 

Decimal

29

40

68

pL

pH

m

[ a1

b1 ]...[ ak

bk ]

[Range]

3

(pL + pH 256) 65535

(0 pL 255 , 0 pH 255)

 

 

m = 20

 

 

 

 

 

 

 

 

 

 

a = 1, 2

 

 

 

 

 

 

 

 

 

 

b = 0, 1, 48, 49

 

 

 

 

 

 

 

 

[Default]

b = 1 [when a = 1]

 

 

 

 

 

 

 

 

b = 0 [when a = 2]

 

 

 

 

 

 

 

[Description] Enables or disables the real-time command specified by a.

pL, pH specify (pL + pH 256) as the number of bytes after pH (m and [a1 b1]...[ak bk]).

 

a

b

Function

 

1

0, 48

DLE DC4 fn m t (fn = 1): Not processed (disabled).

 

 

1, 49

DLE DC4 fn m t (fn = 1): Processed (enabled).

 

2

0, 48

DLE DC4 fn a b (fn = 2): Not processed (disabled).

 

 

1, 49

DLE DC4 fn a b (fn = 2): Processed (enabled).

[Note]

If graphics data includes a data string matching DLE DC4 (fn = 1 or 2), it is

recommended to use this command in advance to disable the real-time commands.

 

TITLE

SHEET

NO

 

EPSON

TM-T81

REVISION

 

 

A

 

 

 

 

 

 

 

Specification

 

 

 

 

 

NEXT

SHEET

 

(STANDARD)

 

77

76

 

 

 

 

 

Page 86
Image 86
Epson T81 specifications GS D pL pH m a1 b1...ak bk