Confidential
EPSON
TITLE SHEET
REVISION
NO
SHEETNEXT
AApp.11 App.10
TM-T81
Specification
(STANDARD)
An example program in which the drawer connected to driv e signal 1 is driven with an ON time of 200
ms is shown below.
PRINT #1,CHR$(&H1B);"p";CHR$(0);CHR$(100);CHR$(250);
GOSUB WAIT300MS
ON time 200 ms OFF time 500 ms
WAIT300MS
300[ms]wait routine ()
RETURN
() Corresponds to α of Formula F-3. Set the value so that it satisfi es Formula F-3 (or include
an internal processing time that is equal to or longer than this wait routine).
The drive signal waveform generated when the drawer is driv en according to the above conditions is
shown in Figure F-2.
Figure F-2 Draw er Dri ve Signal Waveform (Formula F-3)
OFF
ON
200 ms α = 300 ms
500 ms