<Function 081> GS ( k pL pH cn fn m

 

(cn = 48 , fn = 81)

[Name]

PDF417: Print the symbol data in the symbol storage area

[Format]

ASCII

GS

(

k

 

pL

pH

cn

fn

m

 

Hex

1D

28

6B

 

pL

pH

cn

fn

m

 

Decimal

29

40

107

pL pH cn fn m

[Range]

(pL + pH 256) = 3

(pL = 3

, pH = 0)

 

 

 

 

cn = 48

 

 

 

 

 

 

 

 

 

 

fn = 81

 

 

 

 

 

 

 

 

 

 

m = 48

 

 

 

 

 

 

 

 

 

[Description] Encodes and prints the PDF417 symbol data in the symbol storage area using the process of GS ( k <Function 080>.

[Notes] Consider that a quiet zone (left, right, upward, and downward space areas, depending on the PDF417 symbol specifications) must be ensured for PDF417 printing.

In standard mode, a symbol higher than 831 dots cannot be printed with this printer.

<Function 082> GS ( k pL pH cn fn m

 

(cn = 48 , fn = 82)

[Name]

PDF417: Transmit the size information of the symbol data in the symbol storage area

[Format]

ASCII

GS

(

k

 

pL

pH

cn

fn

m

 

Hex

1D

28

6B

 

pL

pH

cn

fn

m

 

Decimal

29

40

107

pL pH cn fn m

[Range]

(pL + pH 256) = 3

(pL = 3

, pH = 0)

 

 

 

 

cn = 48

 

 

 

 

 

 

 

 

 

 

fn = 82

 

 

 

 

 

 

 

 

 

 

m = 48

 

 

 

 

 

 

 

 

 

[Description] Transmits the size information for the encoded PDF417 symbol data in the symbol storage area using the process of GS ( k <Function 080>.

[Notes] This function does not print.

The size information does not include a quiet zone (left, right, upward, and downward space areas, depending on the PDF417 symbol specifications).

 