Confidential
EPSON
TITLE SHEET
REVISION NO
SHEETNEXT
9 8
TM-T81
Specification
(STANDARD) A
1.10 EMI and Safety Standards Applied
EMC is measured using Seiko Epson’s AC adapter.
1) Europe CE marking:
Directive: 89/336/EEC
EN55022 Class B
EN55024
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Safety Standard: EN60950
2) North America EMI: F CC/ ICES-003 Class A
Safety standards: UL1950/CSA C22.2 No.950
Conditions of Acceptability
1) This component has been judged on the basis of the required spacing in the Standard for
Information Technology equipm ent, Incl uding Elect rical B usiness Equipment, UL 1950 and CSA
C22.2 No. 950, Sub-clause 2.9, which would cover the com ponent itself if submitted for Listing.
2) This unit is intended to be supplied by a S E LV circuit only.
3) The terminals and connectors hav e not been evaluated for field wiring.
1.11 Reliability
1) Life:
Mechanism: 15,000,000 lines
NOTE: Assumed in the condition that printing repeats for 10 lines
feeding for 15 lines with 4.23 mm l ine spacing.
T her m al head: 100 million pulses, 100 km
Aut o cutter: 1,500,000 cuts
(End of life is defined to hav e reached the end of its life when it
reaches the beginning of the Wearout Peri od. )
2) MTBF: 360,000 hours
(Failure is defined as Random Fai lure occurring at the time of the
Random Failure Period.)
3) MCBF: 52,000,000 lines
(This is an average failure inter val based on failures relating to
wearout and random failures up to the life of 15 million lines.)