Confidential

1.10 EMI and Safety Standards Applied

EMC is measured using Seiko Epson’s AC adapter.

1) Europe

CE marking:

 

 

Directive: 89/336/EEC

 

 

EN55022 Class B

 

 

EN55024

 

 

IEC61000-4-2

 

 

IEC61000-4-3

 

 

IEC61000-4-4

 

 

IEC61000-4-5

 

 

IEC61000-4-6

 

 

IEC61000-4-11

 

Safety Standard: EN60950

2) North America

EMI:

FCC/ICES-003 Class A

Safety standards: UL1950/CSA C22.2 No.950

Conditions of Acceptability

1)This component has been judged on the basis of the required spacing in the Standard for Information Technology equipment, Including Electrical Business Equipment, UL 1950 and CSA C22.2 No. 950, Sub-clause 2.9, which would cover the component itself if submitted for Listing.

2)This unit is intended to be supplied by a SELV circuit only.

3)The terminals and connectors have not been evaluated for field wiring.

1.11Reliability

1)Life:

Mechanism:

15,000,000 lines

 

NOTE: Assumed in the condition that printing repeats for 10 lines

 

feeding for 15 lines with 4.23 mm line spacing.

Thermal head:

100 million pulses, 100 km

Auto cutter:

1,500,000 cuts

 

(End of life is defined to have reached the end of its life when it

 

reaches the beginning of the Wearout Period.)

2) MTBF:

360,000 hours

 

(Failure is defined as Random Failure occurring at the time of the

 

Random Failure Period.)

3) MCBF:

52,000,000 lines

 

(This is an average failure interval based on failures relating to

 

wearout and random failures up to the life of 15 million lines.)

TITLE

EPSON

TM-T81

SHEET

NO

 

REVISION

 

 

Specification

 

 

 

 

NEXT

SHEET

(STANDARD)

A

9

8

 

 

 

 

 

 

Page 18
Image 18
Epson T81 specifications EMI and Safety Standards Applied, Reliability, Emi