Programmer’s Guide, cont’d

Command/response table for SIS commands (Cont’d)

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

View ties, gain, volume, mutes, presets, and DSVP (continued)

View DSVP (sync frequency)

 

 

LS

 

,

 

 

 

 

 

 

 

 

X1

X15

 

X15

 

View connections

0LS

 

 

1

 

2•...•

 

n

X16

X16

X2

(CrossPoint 450 Plus only)

 

 

 

 

 

 

 

 

 

 

 

 

Each X16 response is the connection status of an input, starting from input 1, n is the maximum number of inputs for this model.

Information requests

Information request

I

V

X2

X

X3

•A

X2

X

X3

V

X2

X

X3

= V size, A

X2

X

X3

=A Size.

Example:

I

V32X16•A32X16

32 video and 32 audio inputs by

 

 

 

 

 

 

 

 

 

 

16 video and 16 audio outputs

 

 

 

 

 

 

 

 

 

 

(CrossPoint 450 Plus 3216 HVA).

Request part number

N

xx-xxx-xx

See appendix B for part #s.

Example:

N

60-468-01

 

 

 

CrossPoint 450 Plus 2424 HVA

 

 

 

 

 

 

 

 

 

 

part # is 60-468-01.

There are up to three separate sets of Extron firmware that the switcher can report on: the CrossPoint/MAV Plus controller firmware, which is the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware update, which is available at www.Extron.com.

Query controller firmware version

Q

 

X17

 

 

Example:

Q

1.23

The factory-installed

 

 

 

 

 

CrossPoint/MAV Plus controller

 

 

 

 

 

firmware version is 1.23

 

 

 

 

 

(sample value only).

Query software version (verbose)

0Q

 

-

 

-

 

Provide a detailed status of the

X17

X18

X18

 

 

 

 

 

Ethernet protocol firmware, the

CrossPoint 450 Plus/MAV Plus controller firmware, and any firmware upgrade. The firmware that is running is marked by asterisk (*). A caret

(^)indicates that the firmware has a bad checksum or an invalid load. ?.?? indicates that firmware is not loaded.

Response description: Ethernet protocol firmware version - controller firmware version - updated firmware version

Example:

0q

 

Description

* indicates the version running

Upload date and time

Response: 1.23-0.14(0.20-32x32 Series - , 00 2000 00:00:00 GMT)-0.25*(0.24-32x32 Series -Thu, 20 Mar 2003 16:39:21 GMT)

Ethernet protocolCrossPoint/MAV firmware versionUpdated firmware version firmware

Request system status

S

X20

X20

X20

X20

X20

X20

X20

X21

X22

X22

X9

X9

Response description: +5V•+3.3V•+2.5V•Fan voltage•-5V•-12V•+12V•Temp•Fan1 RPM•Fan2 RPM•Primary PS•Secondary PS

Example:S

Fans receiving 11.52 V Secondary power supply is on and Ok

4.98•3.30•2.55•11.52•-5.21•-12.35•11.65•78.80•753•774•1•1

5V

 

power system at 4.98V

 

 

 

Fan 1 rotating at 753 RPM