Rear Panel Controls

The rear panel has a Reset button that initiates four levels of matrix switcher resets. Press and hold the button while the switcher is running or while you apply power to the switcher for different reset levels.

Performing soft system resets

The CrossPoint 450 Plus and MAV Plus switchers have three soft resets available that restore various tiers of switcher settings to their default settings.

Events (mode 3) reset — This function toggles the monitoring of events on or off (if events monitoring was on, this function turns it off; if it was off, it is turned on).

IP settings (mode 4) reset — The IP settings reset performs the following functions:

￿

￿

￿

￿

￿

￿

Enables Arp program capability

Resets the IP address to the factory default (192.168.254.254)

Resets the subnet mask to the factory default (255.255.0.0)

Resets the gateway address to its factory default (0.0.0.0)

Turn DHCP off

Turn events off

IP settings reset does not replace any user-installed firmware.

Absolute (mode 5) reset — Absolute reset restores the switcher to the default factory conditions. This function is identical to the Esc ZQQQ SIS command, see chapter 4, “Programmer’s Guide”).

Perform a soft reset of the switcher as follows:

CrossPoint 450 Plus and MAV Plus Switchers • Operation 3-53