Installationstallation, cont’d

Mounting the Switcher

The matrix switchers are housed in rack-mountable, metal enclosures with 19" rack ears. The amount of vertical rack space required for each switcher is as follows:

2U high enclosure

MAV Plus 84, 88, 124, and 128 HDA and HD

MAV Plus 84, 88, 124, 128, and 1212 SVA, and SV

MAV Plus 84, 88, 124, 128, 816, 1212, 168, and 1616 AV, AV RCA, V, and A

MAV Plus 164 A

3U high enclosure

CrossPoint 450 Plus 84, 88, 124, and 128 HV and HVA

MAV Plus 168, 816, and 1616 SVA and SV

4U high enclosure

MAV Plus 168, 816, and 1616 HDA and HD

5U high enclosure

MAV Plus 2412, 2424, 3216, 3232 AV, V, and A

6U high enclosure

CrossPoint 450 Plus 816, 168, and 1616 HV and HVA

8U high enclosure

CrossPoint 450 Plus 2412 and 2424 HV and HVA

10U high enclosure

CrossPoint 450 Plus 3216 and 3232 HV and HVA

UL requirements

The following Underwriters Laboratories (UL) requirements pertain to the installation of the matrix switcher into a rack (figure 2-1).

1.Elevated operating ambient temperature — If installed in a closed or multi- unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum 122 °F (50 °C) (CrossPoint 450 Plus) or 113 °F (45 °C (MAV Plus) ambient temperature (Tma) specified by Extron.

2.Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

3.Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

4.Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips.

Mounting instructions

1. Insert the switcher into the rack, aligning the holes in the mounting bracket with those in the rack.

2-2 CrossPoint 450 Plus and MAV Plus Switchers • Installation

Page 25