Matrix Software, cont’d

Hardware status — Provides an overall view of the status of the matrix switcher, including the primary and secondary power supply status and the individual voltages, the fan and temperature status, the Remote RS-232/RS-422 port configuration, and the installed and updated firmware status (figure 5-14).

Figure 5-14 — Status window

Green — Proper operation.

Red — Component has failed.

White — Components are not installed.

The CrossPoint 450 Plus and MAV Plus switchers are not available in custom configurations. Each model has all available monitored components, such as power supplies and fans, installed. If you see the white “not installed” indication, the “not installed” component probably became disconnected during shipment or rough handling.

Smaller switchers (16 x 16 matrix sizes and smaller) do not show the power supply and fan status blocks.

Name presets — Allows you to assign a name to each of the 32 memory presets.

Preset names are limited to 12 uppercase and lowercase alphanumeric characters, space, and the _ and / characters.

The following characters are invalid in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

Show RS-232 strings — Displays the ASCII commands that are used by the current configuration. You can refer to these for SIS command programming.

I/O group settings — Allows you to establish I/O groups.

Room configuration — Allows you to assign outputs to rooms or delete outputs from rooms.

A Room is a subset of outputs that are logically related to each other, as determined by the operator. The CrossPoint 450 Plus or MAV Plus switcher supports up to 10 rooms, each of which can consist of from 1 to 16 outputs.

Initialize — Initializes and clears any or all of the following: ties, presets, audio configuration, preset names, icon names, and icons.