1 6

9

5

6 feet

(1.8 m)

Part #70-335-01

Tip

Ring

Sleeve (Gnd)

9-pin D

Connection

TRS Plug

Pin 2

Computer's RX line

Tip

Pin 3

Computer's TX line

Ring

Pin 5

Computer's signal ground

Sleeve

Figure 2-24 — Optional 9-pin TRS RS-232 cable

This port is independent of the rear panel Remote port and is not affected by changes to the rear panel port’s protocol. This front panel port’s protocol can be changed, under SIS command control only. See the Command/Response table for IP SIS commands, in chapter 4, “Programmer’s Guide”, to configure all ports under SIS control.

A front panel Configuration port connection and a rear panel Remote port connection can both be active at the same time.

This port is RS-232 only, with its default protocols as follows:

9600 baud

no parity

• 8 data bits

1 stop bit

no flow control

 

The maximum distances from the matrix switcher to the controlling device can vary up to 200 feet (61 m). Factors such as cable gauge, baud rates, environment, and output levels (from the switcher and the controlling device) all affect transmission distance. Distances of about 50 feet (15 m) are typically not a problem. In some cases the matrix switcher may be capable of serial communications via RS-232 up to 250 feet (76 m) away.

CrossPoint 450 Plus and MAV Plus Switchers • Installation 2-19

Page 42