Command/Response Table for SIS Commands

Symbol Definitions:

= Carriage return/line feed

= Carriage return (no line feed)

= Space

Esc

X1

X2

X3

X4

X5

X6

X7

X8

X9

X10

X11

X12

X13

X14

X15

X16

= Escape key

Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are reported as 2-digit numbers in the response.

= Input number

01 – (maximum number of inputs for your model)

= Input number (for tie)

00 – (maximum number of inputs) (00 = untied)

= Output number

01 – (maximum number of outputs for your model)

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

= Audio gain

0 – 24

(1 dB/step)

= Audio attenuation

1 – 18

(1 dB/step)

= Volume adjustment range

0 – 64

(1 dB/step except for 0-to-1, which is 13 dB)

= Room # (for room presets)

10 max. (each can have up to 10 presets ( X12 s) assigned)

A Room is a subset of operator-selec ted outputs that relate to each other. The CrossPoint 450 Plus or MAV Plus switcher supports up to 10 rooms, each of which can consist of from 1 to 16 outputs.

= Mute, Lock mode, power supply

(0 = off/mode 0/not Ok, 1 = on/mode 1/Ok, 2 = mode 2)

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

= Global preset #

0, 01-32 maximum (0 = current configuration)

= Room preset #

10 maximum (0 = current configuration for room)

A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory, it becomes the current configuration.

= RGB delay interval

Delay in ½ second increments (10 maximum)

= Video/audio mute:

0

= no mutes

 

1

= video mute

 

2

= audio mute

 

3

= video and audio mute

= Sync frequency

xxx.xx (frequency in Hz (V) or kHz (H))

= Connection status

0 = no input connected

 

1

= input connected

X17

X18

X19

X20

X21

X22

=Firmware version number to second decimal place (x.xx)

=Verbose firmware version-description-upload date/time. See page 4-16.

= Name

12 characters maximum for input, output, global preset,

 

 

 

and room preset names.

 

 

 

11 characters maximum for room names.

 

 

 

Upper- and lower-case alphanumeric characters and

 

 

 

_ / and spaces are valid.

 

 

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

 

 

= Voltage

Positive or negative voltage and magnitude

= Temperature

Degrees Fahrenheit

= Fan speed

RPM

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide