Operation, cont’d

 

 

I/O groups are protected when front panel lock mode 2 is selected. You can

 

 

view the groups in lock mode 2, but not change them from the front panel.

 

 

If front panel lock mode 2 is selected and you try to perform steps 4 through 6,

 

 

the actions are ignored and the Enter, RGBHV/Video, and Audio buttons flash.

4.

Press and release the input 1 through 4 and output 1 through 4 buttons

 

(figure 3-33).

Press and release the Input 1 through Input 4 buttons.

The selected buttons light green.

1 2 3 4 5 6 7 8 15 16

17 18 19 20 21 22 23 24 31 32

I

N P U T S

Press and release the Output 1 through Output 4 buttons. The selected buttons light green.

1 2 3 4 5 6 7 8 15 16

17 18 19 20 21 22 23 24 31 32

O U T P U T S

Figure 3-33 — Assign inputs and outputs

5.

Press and release the Preset button to select group 2 (figure 3-34).

Press and release the Preset button to select group 2.

The button lights amber to indicate the selection.

C O N T R O L

ENTER

PRESET

VIEW

ESC

 

 

Group # 1

2

3

4

Figure 3-34 — Select an I/O group

3-24 CrossPoint 450 Plus and MAV Plus Switchers • Operation