Operation, cont’d

The serial port settings are protected when front panel lock mode 2 is selected. You can view the settings in lock mode 2, but not change them from the front panel.

If front panel lock mode 2 is selected and you try to perform step 3, the actions are ignored and the Enter, RGBHV/Video, and Audio buttons flash.

3. To change a value, press and release the button that relates to the desired value (figure 3-80).

Press and release the button(s) to configure the port as

follows:

 

Baud rate:

 

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

Serial protocol:

 

RGBHV/Video — RS-232

Audio — RS-422/RS-485

The selected buttons blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

C O N T R O L

ENTER

PRESET

VIEW

ESC

 

 

I / O

RGBHV AUDIO

= Blinking button

Figure 3-80RS-232/RS-422 and baud rate selection

4. Press and release an input or output button to exit the Serial Port Configuration mode (figure 3-81).

Press and release an

All Control and I/O buttons return to unlit or background illumination.

input or output button.

C O N T R O L

I / O

 

 

 

 

 

 

5

ENTER

PRESET

VIEW

ESC

RGBHV

AUDIO

 

 

 

 

 

 

Figure 3-81 — Exit Serial Port Configuration mode

3-52 CrossPoint 450 Plus and MAV Plus Switchers • Operation

Page 95
Image 95